Connections For Semi-Automatic Or Automatic Wire Feeder Control - Red-D-Arc DC-600 Operator's Manual

Table of Contents

Advertisement

C-3
12. Connect stick or air/carbon arc electrode and work
cable. See Figure C.2.
a. Insert the electrode and work cables through
the strain relief loop on the right side (facing
the front of the machine) of the DC-600.
b. Connect the electrode cable to the "Positive"
terminal on the right side of the MULTI-
PROCESS SWITCH.
c. Connect the work cable to the "Negative" ter-
minal on the right side of the MULTI-
PROCESS SWITCH.
NOTE: The instructions above are for connecting
the stick polarity positive. To change the polarity,
turn the DC-600 OFF, and reverse the cables.
NOTE: When it is not necessary to have separate
ground cables for stick and semi-automatic or
automatic welding, connect a jumper from the
MULTI-PROCESS SWITCH "Work" terminal to
the MULTI-PROCESS SWITCH "negative" termi-
nal. See Figure C.2.
To operate the MULTI-PROCESS SWITCH, refer to
the operating instructions on the switch nameplate.
ACCESSORIES
CONNECTIONS FOR SEMI-AUTO-
MATIC OR AUTOMATIC WIRE FEED-
ER CONTROL
1. Set the DC-600 ON/OFF switch to OFF.
2. Set the DC-600 LOCAL/REMOTE switch to
REMOTE.
3. Set the DC-600 OUTPUT TERMINALS switch to
REMOTE.
4. Set the DC-600 MODE switch to the welding
process being used.
5. Refer to the proper connection diagram in the DIA-
GRAMS section for more information.
DC-600
C-3