Red-D-Arc DC-600 Operator's Manual page 26

Table of Contents

Advertisement

C-2
The MULTI-PROCESS SWITCH has two sets of out-
put terminals. You connect the wire feeder unit cables
to the set of terminals on the left side of the box and
the stick or air/carbon arc cables to the set of termi-
nals on the right side (facing the front of the machine)
as shown in Figure C.1. The output terminals are pro-
tected against accidental contact by hinged covers.
When the MULTI-PROCESS SWITCH is in the "Stick
or
Air/Carbon
Arc"
terminals are energized. The wire feeder nozzle or
gun and electrode are not electrically "hot" when in
this mode.
Follow these steps to install the MULTI-PROCESS
SWITCH:
1. Confirm that the DC-600 POWER ON/OFF switch
is in the OFF position.
2. Disconnect main AC input power to the DC-
600.
3. Open the terminal strip hinged cover located on
the Case Front Assembly.
4. The MULTI-PROCESS SWITCH is mounted to
the case front with four 1/4" self-tapping screws.
The screw holes are 13.8" apart side to side and
4.5" apart top to bottom, Run one of the 1/4"
screws part way in and out of the screw holes to
open them up. Make sure that the two sleeved
control leads do not get pinched when hanging
the switch; route them out the side to the right of
the switch. Support the switch in position and start
the four screws, then tighten them.
5. Route the MULTI-PROCESS SWITCH control
leads through the strain-relief box connectors and
into the terminal strip. Connect wire feeder control
cable as specified in specific connection diagram
and make other terminal strip connections as
specified on the connection diagram for the
Lincoln wire feeder being used.
6. Connect the control leads from the MULTI-
PROCESS SWITCH to terminals #2 and #4 on
the DC-600's terminal strip.
7. Connect the right cable from the MULTI-
PROCESS SWITCH (facing the front of the
machine) to the DC-600 positive (+) output termi-
nal. See Figure C.2.
ACCESSORIES
position,
only
those
21+
21-
41 4
2
31 32
NEGATIVE (–)
OUTPUT
STUD
ELECTRODE
CABLE
WORK
WIRE
FEEDER
ELECTRODES
WORK
CABLE
JUMPER (IF NEEDED
SEE INSTRUCTIONS)
FIGURE C.4 - MULTI-PROCESS SWITCH
CABLE CONNECTIONS.
8. Connect the left cable from the MULTI-PROCESS
SWITCH (facing the front of the machine) to the
DC-600 negative (-) output terminal. See Figure
C.2.
9. Connect the wire feeder electrode and work
cables. See Figure C.2.
a. Insert the wire feeder electrode and work
cables through the strain relief loop on the left
side of the DC-600 (facing the front of the
machine).
b. Connect the wire feeder electrode and work
cables
to
the
terminals on the left side of the MULTI-
PROCESS SWITCH.
10. Connect wire feeder control cable and make other
terminal strip connections as specified on the
connection diagram for the Lincoln wire feeder
being used.
11.
Set the DC-600 OUTPUT TERMINALS switch to
REMOTE.
DC-600
C-2
TERMINAL
STRIP COVER
BOX
CONNECTOR
75 76 77
CONTROL
LEADS
POSITIVE (+)
+
OUTPUT
STUD
ELECTRODE
CABLE
+
STICK AIR/CARBON
ARC WELDING
EQUIPMENT
WORK
CABLE
electrode
and
work