Welding Capability; Meaning Of Graphical Symbols On Case Front - Red-D-Arc DC-600 Operator's Manual

Table of Contents

Advertisement

B-3

WELDING CAPABILITY

The DC-600 has the following Output and Duty Cycle based on operation for a 10 minute period:
MEANINGS OF GRAPHICAL SYMBOLS ON CASE FRONT
Input POWER ON/OFF Switch
SYMBOL
Pilot Light
Input power on when light is illuminated
(except for abnormal conditions).
Always indicates POWER ON/OFF
switch is in ON position.
OUTPUT CONTROL
Clockwise Increase of Output
TERMINALS ON/REMOTE Switch
Remote Control of Output Terminals
(Energized or Non-Energized)
OPERATION
600 Amps, 44 Volts at 100%
680 Amps, 44 Volts at 60%
750 Amps, 44 Volts at 50%
MEANING
ON
OFF
INPUT POWER
OUTPUT VOLTAGE
AND CURRENT
Voltage and Current
OUTPUT TERMINALS
ENERGIZED
LOCAL/REMOTE Switch
SYMBOL
Control Of Output Voltage and
Current is Via DC-600's Control Dial
Remote Control of Output Voltage
MODE Switch
CC STICK: Shielded Metal Arc
Welding (SMAW), this switch
position is also used for Air
Carbon Arc Cutting (AAC)
Constant Voltage Submerged
CV INNERSHIELD: Flux Cored
Arc Welding (FCAW), this switch
position is also used for Gas
Metal Arc Welding (GMAW).
Output Terminal Connections
Positive Output Terminal
Negative Output Terminal
WARNING Identification
Warning and Caution Identification
Circuit Breaker
Circuit Breaker (two breakers: 15A
for 115V circuit and 10A for 42V
DC-600
B-3
MEANING
and Current
CV SUBMERGED ARC:
Arc Welding (SAW)
circuit)

Advertisement

Table of Contents