Route The Cables - Axis Q8741-E Installation Manual

Q87 series bispectral ptz network camera
Hide thumbs Also See for Q8741-E:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
AXIS Q87 Bispectral PTZ Network Camera Series
1
Conduit cover clip
2
Conduit cover
3
Screw hole (x4)
5. For conduit installations only: remove the two conduit cover clips followed by the
conduit cover.
6. Attach the base unit to the mounting surface using the appropriate fasteners in the
four screw holes.

Route the cables

WARNING
Risk of electric shock. The product shall be grounded using both the protective earth wire
in the power cable and the grounding braid. Make sure both ends of the protective earth
wire and the grounding braid are in contact with their respective grounding surfaces.
Important
Use only cables that comply with the specified cable area. For more information, see
Cable thickness on page 30.