Attaching The Stop Switch Guard - Pro-face GP-4311HT Installation Manual

Gp4000h series
Table of Contents

Advertisement

Installation

Attaching the Stop Switch Guard

NOTE: When the stop switch guard is attached, the emergency stop switch or the stop
switch is not conformable to safety standards (EC Machinery Directive IEC60204-1, etc.).
If conforming to the safety standards is required, do not use the stop switch guard (included
in this product).
Step
Action
1
Prepare the stop switch guard and 3 installation screws, included
with this product.
2
Remove the stop switch guard hole covers at two places beside
the emergency stop switch (or the stop switch).
1 Stop switch guard hole covers
3
Align the three screw holes of the stop switch guard with the
screw holes of this product. And fasten the two points in the front,
and the one point in the rear of this product with screws. The
necessary torque is 0.5 N•m (4.4 lb-in).
BROKEN ENCLOSURE
Do not exert more than 0.5 N•m (4.4 lb-in) of torque when tightening the
screws.
Failure to follow these instructions can result in equipment damage.