F.10 MEMS SENSOR TO MULTIPLEXER WIRING
Up to sixteen Uniaxial MEMS sensors are connected to the Canary six wire Multiplexer through
the weather tight strain relief fittings mounted to the Datalogger enclosure; with the final
connection made to the terminal blocks mounted on the Multiplexer. Each terminal block, or
Multiplexer channel, consists of seven clamp connections. A sample Uniaxial MEMS connection
is as follows for terminal block #1.
Terminal Block
Location
Up to eight Biaxial MEMS sensors are connected to each Canary six wire Multiplexer through
the weather tight strain relief fittings mounted to the Datalogger enclosure; with the final
connection made to the terminal blocks mounted on the Multiplexer. Each terminal block, or
Multiplexer channel, consists of seven clamp connections. A sample biaxial MEMS connection
is as follows for terminal blocks #1 and #2:
Terminal Block
Location
Note: * Jumpers required for Sensor Power and Sensor Ground
Sensor Wire Color
1H1
White's Black
1L1
1H2
Green's Black
1L2
1H3
Red's Black
1L3
Shield
Sensor Wire Color
1H1
White's Black
1L1
1H2
Blue's Black
1L2
1H3
Red's Black *
1L3
Shield
2H1
Green's Black
2L1
2H2
No Connection
2L2
No Connection
2H3
Red's Black *
2L3
Shield
Description
White
MEMS Output +
MEMS Output -
Green
Thermistor Output+
Thermistor Output-
Red
+12V Power
Power Ground
Bare
Cable Shield
Description
White
A axis Output +
A axis Output -
Blue
Thermistor Output+
Thermistor Output-
Red *
+12V Power
Power Ground
Bare
Cable Shield
Green
B axis Output +
B axis Output -
Red *
+12V Power
Power Ground
Bare
Cable Shield
--
--