Setting Sequence Conditions; Executing, Pausing, And Stopping Sequences - Kikusui PCR500LE User Manual

Ac power supply pcr-le series
Table of Contents

Advertisement

Using the Sequence Function (Cont.)

Setting sequence conditions

The items that you set here are shared between all steps.
„ Setting the starting step number and the ending
step number
On the sequence screen, press COND (F4) to set the starting
step number and the ending step number.
LOAD
OUTPUT
OFF
10.00Hz
A rms
0.00
0.0
L
RANGE
SEQUENCE
START STEP: 000
STOP
END STEP: 000
LOOP:
Sequence
STOP
RUN
LOOP
COND
LOAD
OUTPUT
A rms
OFF
0.00
SEQ. CONDITION
START STEP : 000
END STEP
: 008
Start Step
000
Item
Title
Description
START STEP Start Step
Sets the starting step number (0 to 599)
END STEP
End Step
Sets the ending step number (0 to 599)
„ Setting the number of repetitions
On the sequence screen, press LOOP (F3) to set the number of
times that the sequence will be repeated.
LOAD
OUTPUT
OFF
10.00Hz
0.00
A rms
RANGE
L
SEQUENCE
START STEP: 000
STOP
END STEP: 000
LOOP:
Loop
3
Item
Title
Description
LOOP
Loop
Sets the number of repetitions (1 to 99 999;
99 999 indicates unlimited repetitions)
„ Setting the polarity of trigger and status output
Press CONFIG (SHIFT+OPR MODE) and then SIG.I/O (F3) to
set the trigger input polarity, the trigger output polarity, and
the status output polarity. The status signal polarity setting is
shared with that of the power line abnormality simulation func-
tion.
LOAD
OUTPUT
OFF
50.00
0.00
RANGE
L
A
rms
CONFIG. MEMU
COM-I/F
SIG.I/O
DISPLAY
LOAD
OUTPUT
A rms
OFF
0.00
CONFIG. SIGNAL I/O POLARITY
TRIG:IN
: POSI
TRIG.OUT : POSI
STAT.OUT : POSI
NEGA
Item
Description
TRIG.IN
NEGA
Sets the trigger input to falling edge
POSI
Sets the trigger input to rising edge
TRIG.OUT
NEGA
Sets the trigger output to falling edge
POSI
Sets the trigger output to rising edge
STAT.OUT
NEGA
Sets the status output to low level
POSI
Sets the status output to high level
62
AC
RESP.M
V rms
1
EDIT
1/2
10.00Hz
V rms
0.0
AC
RESP.M
0.0
V rms
3
AC
RESP.M
Hz
28.1
V
rms
MODEL ID
1/2
10.00Hz
V rms
0.0
POSI

Executing, pausing, and stopping sequences

After you have finished setting the steps and the sequence
conditions, you can execute the sequence.
On the sequence screen, press "RUN" (F1) to execute the se-
quence.
You cannot execute the sequence in the following situations.
• When the voltage range is set to the L range and there is a
step whose voltage exceeds the output voltage setting range
(Switch the range to the H range, or set the output voltage so
that it is within the L range).
• When you have configured the PCR-LE Series so that it does
not turn output off when the current limit is exceeded (DIS-
ABLE).
• When the regulation adjustment or soft sensing compensa-
tion function is in use.
• When the L range is selected and a step's ACVolt or DCVolt
setting is outside of the L range.
• When the voltage or frequency is set to a value outside the
corresponding limits.
• If there is a step where the trigger wait setting (TRIG.IN) and
the sudden phase change setting (PHAS.CHG) are both
turned on.
LOAD
OUTPUT
OFF
10.00Hz
A rms
0.00
L
RANGE
SEQUENCE
START STEP: 000
STOP
END STEP: 000
LOOP:
Sequence
STOP
RUN
LOOP
COND
LOAD
OUTPUT
ON
10.00Hz
A rms
6.87
28.1
L
RANGE
SEQUENCE
RUN
001
0:00:01
STEP
Sequence
RUN
STOP
PAUSE
While a sequence has been paused
SEQUENCE
PAUSE
004
0:00:04
STEP
Sequence
PAUSE
STOP
CONTINUE
Item
Title
Description
STOP
Sequence
Stops a sequence that is being executed
PAUSE
Pauses a sequence that is being executed
CONTINUE
Resumes a sequence that has been paused
You can also resume the execution of a sequence that has
been paused by applying a trigger signal to the SEQ TRIG IN
terminal.
AC
RESP.M
V rms
0.0
1
EDIT
AC
RESP.M
V rms
1/3
LOOP
1/3
LOOP
PCR-LE series