Programming
Totalizer Pulse Output
The pulse output parameter can be enabled or disabled� When enabled this output
generates 20 mS duration pulse for every time the least significant digit of the totalizer
increments� The amplitude of the pulse is dependent on the voltage level of the supply
connected to the pulse output and is limited to a maximum 30V DC� Press UP or OIGHT to
scroll to ON or OFF� Press ENTEO to save and advance to the PASSWORD parameter�
Password
The PASSWORD setting restricts access to PROGRAM mode� Initially, the password is set to
all zeros and any user can modify the parameter settings in PROGRAM mode� To change the
password, enter any four digit code� Press UP to increment the digit, and OIGHT to advance
to the next digit� Press ENTEO to store the password and advance to RST PSWD� The new
password is now required to enter PROGRAM mode� With this password set, any user is able
to reset the stored totals on the monitor�
Oeset Password
The RST PSWD restricts resetting the totals on the monitor� The PASSWORD must also be set
to restrict the total reset� Initially, the password is set to all zeros and any user can reset the
stored totals on the monitor� To change the password, enter any four digit code� Press UP to
increment the digit, and OIGHT to advance to the next digit� After entering all digits, press
ENTEO to store the password and return to RUN mode� The reset password is now required
to reset the totals on the monitor�
Oun Mode
Oeset Total
To reset the monitor total display, in RUN mode press MENU and ENTEO simultaneously� If
the RST PSWD has been set to something other than the default, you must enter the new
password before the monitor will reset� The monitor flashes
TOTAL RST and returns to RUN mode at the conclusion of the reset procedure�
Store Total
The current total can be manually stored in the monitor's flash memory� Use this feature
prior to replacing the battery� Press and hold ENTEO for 2 seconds� The display responds
with a flashing TOTALSVD and then returns to RUN mode�
Automatic Store Total
The monitor is equipped with a store total feature that works automatically, saving the
current total to flash memory� The frequency of saves depends on the power supply option
chosen�
Battery Powered: Once per hour and just before a low battery condition turns the unit off�
Loop Powered:
Once every ten minutes�
Page 8
DSY-PM-00276-EN-04
March 2017