User Calibration Options; How Do I Access User Calibration Settings; User Calibration Pages; Autotack Angle (Sailboat Only) - Raymarine ST7002 Operating Manual

Raymarine smartpilot controller operating guide st7002
Hide thumbs Also See for ST7002:
Table of Contents

Advertisement

Chapter 2: Advanced Operation

2.4 User Calibration Options

The calibration information in this handbook relates to only those settings that
can be adjusted during normal operation (USER CAL). For information on all
available calibration settings, see
Many of the settings are sailboat specific and will only be displayed if your vessel
Note:
type is set to SAILBOAT

How do I access User Calibration settings?

You can only access the calibration mode from Standby mode:
1. With the SmartPilot in Standby mode, press and hold the standby button for
2 seconds. The display will change to show DISPLAY CAL.
2. Press the disp button once, the display will now show USER CAL.
3. Press auto to enter User Calibration.
The first page of User Calibration will now be displayed.
4. To access other User Calibration pages, press disp to scroll down through the
items within that grouping:
5. When you reach an item you wish to adjust, use the -1, +1, -10 and +10 but-
tons (as appropriate) to change the value.
6. When you have made all the changes you want to make, press and hold
standby for two seconds to exit calibration mode and save changes.

User Calibration pages

AutoTack angle (SAILBOAT only)

The AutoTack angle is the angle through which the boat will turn when you select
an automatic tack.
Screen Text
AUTO TACK
SmartPilot Commissioning Guide.
.
Options
40° to 125° in 1° steps
23