Raymarine C140w User Reference Handbook page 123

C-series widescreen multifunction display
Hide thumbs Also See for C140w:
Table of Contents

Advertisement

Measuring using floating VRM and EBL
You can use the VRM/EBL float function to measure the range and
bearing between any two points on the radar screen. This function
allows you to move the VRM/EBL centre away from your boat's
position and onto a target. You can then change the radius of the
VRM to determine the distance between two points and change the
angle of the EBL, relative to its new origin, to obtain the bearing.
Creating a VRM or EBL on the radar display
1. In the Radar application, press the VRM/EBL 1 softkey until the
ON option is selected.
2. Press the ADJUST VRM softkey.
3. Using the rotary control, adjust the VRM to the required size.
4. Press the ADJUST EBL softkey.
5. Using the rotary control, adjust the EBL to the required angle.
6. Press the OK button to save the settings.
Using radar
7. Repeat Steps 1 to 6 to create a second VRM/EBL if required,
this time using the VRM/EBL 2 softkey.
Note: The first VRM/EBL will be placed at a location of 1/3 of
the current range and 030° relative to your vessel's head. If this
setting is adjusted, the display will retain the adjustments and use
them when the VRM/EBL is next enabled.
Creating a floating VRM or EBL on the radar
display
1. If you have already created a VRM or EBL, skip to Step 7.
Otherwise, in the Radar application, press the VRM/EBL 1
softkey until the ON option is selected.
2. Press the ADJUST VRM softkey.
3. Using the rotary control, adjust the VRM to the required size.
4. Press the ADJUST EBL softkey.
5. Using the rotary control, adjust the EBL to the required angle.
6. Press the OK button to save the settings.
7. Using the trackpad, position the cursor over the VRM or EBL.
8. Press the FLOATING EBL softkey.
9. Press the ADJUST FLOAT softkey.
10. Using the trackpad, move the float to define the first point for
your measurement.
11. Press the OK button twice.
12. Press the ADJUST VRM softkey
13. Using the trackpad, move the VRM over the second target.
14. The ADJUST VRM softkey tells you what the measurement is
between the two targets.
15. Press the OK button.
123

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C90wC series c120wC-seriesC120wC140

Table of Contents