(2) Option FR-A7AX terminal
Terminal
Terminal Name
Symbol
Digital signal
X0 to X15
input
Data read
DY
timing
input signal
Common
SD
(sink)
(inverter)
External
transistor
PC
common
(inverter)
(source)
Input the digital signal at the relay contact or open collector terminal.
Using Pr. 360 , speed or position command is selected as the command signal
entered.
Used when a digital signal read timing signal is necessary. Data is read only
during the DY signal is on.
By switching the DY signal off, the X0 to X15 data before signal-off can be
retained.
Common terminal for digital and data read timing signals.
Use terminal SD of the inverter.
When connecting the transistor output (open collector output), such as a
programmable controller, connect the external power common (+) to this
terminal to prevent a fault occurring due to leakage current.
ORIENTATION CONTROL
Description
3
25