12.7. Odour Cut Control

• Odour cut operation removes the odour generated at indoor heat exchanger by using drain water come out from indoor heat
exchanger.
• Press "Odour" button at remote control to enable odour cut operation.
• Odour cut operation starts when compressor or thermostat is on.
Thermostat &
Compressor ON/OFF
Time
Cooling
Soft Dry

12.8. Vertical Airflow Direction Control

Auto Control
• When the vertical airflow direction is set to Auto using the remote control, the louver swings up and down as shown in the
diagram.
• When stop operation using the remote control, the discharge vent is reset, and stop at the closing position.
• During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At that condition, the
louver will stop swinging and rest at the upper limit.
Manual Control
• When the vertical airflow direction is set to Manual using the remote control, the automatic airflow is released and the airflow
direction louver move up and down in the range shown in the diagram.
• The louver can be adjusted by pressing the button to the desired louver position.
• When stop operation using the remote control, the discharge vent is reset, and stop at the closing position.

12.9. Horizontal Airflow Direction Control

• The horizontal airflow direction louvers can be adjusted manually by hand.
Thermostat & Compressor ON
40 sec.
50sec.
Off
SSLo
Normal
Operation
Off
SSLo
SLo
Thermostat & Compressor OFF
-
20 sec.
160 sec.
SSLo
Off
SSLo
Off
31
Thermostat & Compressor ON
20 sec.
40 sec.
50 sec.
SSLo
Off
SSLo
SSLo
Off
SSLo
-
Normal
Operation
SLo