Indicator lamp burner failure
1x blinking
– The exhaust temperature limiter has
been triggered.
Set the appliance switch to "0/OFF".
Allow device to cool down.
Turn on the appliance.
– Error occurs repeatedly.
Inform Customer Service.
2x blinking (option)
– The flame sensor turned the burner off.
Inform Customer Service.
3x blinking
– System care detection defective
Inform Customer Service.
4x blinking
– Temperature sensor defective
Inform Customer Service.
Indicator lamp service
– Service interval
Perform service work.
Fuel indicator lamp glows
– Fuel tank empty.
Refill fuel.
Indicator lamp system care is
illuminated
Note: Burner can operate 5 more hours.
– System care tank is empty, due to tech-
nical reasons a remainder stays in the
tank.
Refill system care.
Indicator lamp system care is
Note: Burner operation no longer possible.
– System care container is empty.
Refill system care.
Appliance is not running
– No power
Check power connection/conduit.
18
blinking
Device is not building up pressure
– Air within the system
Vent pump:
Set dosing value for detergent to "0".
With open hand spray gun turn device
on and off multiple times with the device
switch.
Open and close the pressure/quantity
regulation at the pump unit with the
hand spray gun open.
Note: By dismantling the high pressure
hose from the high pressure connection the
venting process is accelerated.
If detergent tank is empty, refill.
Check connections and conduits.
– Pressure is set to MIN
Set pressure to MAX.
– Sieve in the water connection is dirty
Clean sieve.
Clean the fine filter; replace it, if neces-
sary.
– Amount of water supply is too low.
Check water supply level (refer to tech-
nical data).
Device leaks, water drips from the
bottom of the device
– Pump leaky
Note: 3 drops/minute are allowed.
With stronger leak, have device
checked by customer service.
Device turns on and off while hand
spray gun is closed
– Leak in the high pressure system
Check high pressure system and con-
nections for tightness.
– 11
EN