No
Problem
1
OCT is disconnected
2
OCT is shorted
3
CTT is disconnected
4
CTT is shorted
5
HST is disconnected (when enabled)
6
HST is shorted (when enabled)
7
OAT is disconnected (when enabled)
8
OAT is shorted (when enabled)
9
TSUC is disconnected (when enabled)
10
TSUC is shorted (when enabled)
11
IPM Fault
12
Bad EEPROM
13
DC under voltage
14
DC over voltage
15
AC under voltage
16
IDU/ODU Communication mismatch
17
No Communication
18
Reserved
20
Heat sink Over Heating
21
Deicing
22
Compressor Over Heating
23
Compressor Over Current
24
No OFAN Feedback
25
OFAN locked
26
Compressor Lock
27
Bad Communication
1 – ON,
0 – OFF
Only one code is shown. Order of priority is 1-24. Diagnostics is continuously
ON as long power is on.