Electra WNG 25 DCI INV Service Manual page 43

Wng led/lcd dci inverter series, indoor / outdoor units, r410a, heat pump
Hide thumbs Also See for WNG 25 DCI INV:
Table of Contents

Advertisement

TROUBLESHOOTING
No
SYMPTOM
8
Compressor is on but
outdoor fan does not
work
9
Unit works in wrong
mode )cool instead of
heat or heat instead of
cool(
10
All components are
operating properly but
no cooling or no heating
11
Compressor is over
heated and unit does not
generate capacity
12
Units goes into
protections and
compressor is stopped
with no clear reason
13
Compressor motor is
generating noise and no
suction occurs
14
Water leakage from
indoor unit
15
Freezing of outdoor unit
in heat mode and
outdoor unit base is
blocked with ice
16
Unit operates with wrong
fan speeds or wrong
frequency
12.2
Checking the refrigeration system
Checking system pressures and other thermodynamic measures should be done when system
is in Test Mode (in Test mode, system operates in fixed settings). The performance curves
given in this manual are given for unit performance in test mode when high indoor fan speed is
selected.
Entering test mode:
Set unit to Cool/16 degrees/High indoor fan speed, or Heat/30 degrees/High indoor fan speed,
and enter diagnostics.
12-2
PROBABLE
CAUSE
Problem with
Check outdoor fan motor according
outdoor electronics
to the procedure in section 12.5.3
or outdoor fan
below, if not OK replace controller
Electronics or
Check RV power connections, if OK,
power connection
Check RV operation with direct
to RV
230VAC power supply, if OK,
Replace outdoor controller.
Refrigerant leak
Check refrigeration system.
EEV problem
Check EEV
Control problem or
Perform diagnostics )See 12.3
refrigeration
below(, and follow the actions
system problem
described.
Phase order to
Check compressor phase order.
compressor is
wrong
Indoor unit
Check and open drainage tube.
drainage tube is
blocked
Connect base heater.
Wrong umper
j
Perform diagnostics (See 12.3
settings
below), and check if units is
operating by EEPROM parameters.
Revision 0
CONTENT
CORRECTIVE ACTION
Service Manual – WNG DCI

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ong 25 dci invWng 35 dci invOng 35 dci inv

Table of Contents