Endress+Hauser Levelflex M FMP40 Brief Operating Instructions page 32

Guided level-radar
Hide thumbs Also See for Levelflex M FMP40:
Table of Contents

Advertisement

Commissioning
ε
Media
DC (
r)
group
1
1.4 to 1.6
– Plastic granulate
– White lime, special cement
2
1.6 to 1.9
– Sugar
– Portland cement, plaster
3
1.9 to 2.5
– Flour
– Grain, seeds
4
2.5 to 4
– Ground stones
– Sand
– Naturally moist (ground)
5
4 to 7
– Sal
– Metallic powder
6
> 7
– Carbon black
– Coa
The lower group applies to very loose or loosened bulk solids. Reduction of the max. possible
measuring range by means of:
• Extremely loose surfaces of bulk solids, e.g. bulk solids with low piled density when filled
pneumatically.
• Build-up, primarily of moist products.
!
Note!
Due to the high diffusion rate of ammonia it is recommended to use the FMP45 with gas-tight
bushing for measurements in this medium.
32
Typical bulk solids
stones, ores
Levelflex M FMP40 FOUNDATION Fieldbus
Typical liquids
– Condensed gases, e.g. N
CO
2
– Liquefied gas, e.g. Propane
– Solvent
– Frigen / Freon
– Palm oi
– Mineral oils, fuels
– Benzene, styrene, toluene
– Furan
– Naphthalene
– Chlorobenzene,
chloroform
– Cellulose spray
– Isocyanate, aniline
– Aqueous solutions
– Alcohols
– Ammonia
Measuring range
bare metallic
PA-coated rope
probes
,
4 m (157"), only
2
coax probe
25 m to 30 m
12,5 m to 15 m
(984" to 1181")
30 m to 35 m
(1181" to 1378")
(984" to 1181")
35 m (1378")
(984" to 1181")
35 m (1378")
35 m (1378")
Endress+Hauser
probes
(492" to 590")
15 m to 25 m
(590" to 984")
25 m to 30 m
25 m to 30 m
35 m (1378")
35 m (1378")