Levelflex M FMP40 FOUNDATION Fieldbus
Supporting probes against warping
• For WHG approval:
For probe lengths ≥ 3 m a support is required (see figur).
• For GL/ABS approval:
Rof probes ∅ 16 mm ≤ 1 m permissible, rod probes ∅ 6 mm not permissible.
2.3.6 Special notes for bulk solids
• In the case of bulk solids, as great a
distance as possible from the fillling
curtain is especially important to avoid
wear.
• In concrete silos, a large distance (B)
should be observed between the probe
and the concrete wall, if possibile ≥ 1 m,
but at least 0.5 m.
• The installation of rope probes must be
carried out of carefully. If possible,
installation should be carried out when
the silo is empty.
• Check the probe regularly for defect.
Endress+Hauser
Probe rod
#
Sleeve bored tight
to ensure electrical
contact between the rod
and sleeve!
Short metal pipe
e.g. welded in place
#
Ø 17...18 mm
Ground the probe
when welding the
sleeve!
Ø <26 mm
B
Mounting
L00-FMP4xxxx-17-00-00-en-055
L00-FMP4xxxx-17-00-00-xx-005
11