SERVICE CHECKS
Problem
Will not spray
Improper spray pattern
Jerky or fluttering spray
Fluid leaking from
Needle Packing Nut (8)
Dripping from Fluid Tip
ACCESSORIES
Part №
42884-214-K5 Cleaning Brush (kit of 5)
SN-26-K4
Color ID Ring Kit (4 colors)
Cause
No pressure to gun.
Adjusting Screw (13) not properly adjusted.
A,B - Material build up on the Air Cap or Fluid Tip.
C,D - Incorrect fluid delivery or viscosity.
Insufficient material in the cup or loose Connector.
Gun fluid passage plugged.
Worn Needle Packing (8).
Loose or damaged Fluid Tip (5).
Worn or damaged Needle Packing (8).
Worn or damaged Fluid Tip (5) or Needle (11).
Stuck Needle Packing (8) or Needle (11).
Loose Adjusting Screw (13).
Description
D
V I L B I S S D I V I S I O N
E
RANSBURG INDUSTRIAL FINISHING KK
15-5 Fuku-ura 1Chome,Kanazawa-ku,Yokohama,Kanagawa,Japan 〒236-0004
℡ 0 4 5 - 7 8 5 - 6 3 7 1
Check air and material lines.
Adjust.
A,B - Clean the Air Cap or Fluid Tip.
C,D - Adjust.
Fill cup or tighten the Connector.
Clean.
Replace.
Tighten or replace.
Replace.
Replace.
Lubricate.
Adjust.
Part №
SSL-10
Gun Lube (60ml)
F a x 0 4 5 - 7 8 5 - 6 5 1 7
4
Correction