[5] CHECKING TEMPERATURE IN THE CONVECTION (Oven) MODE

The following test procedure should be carried out with the oven is a fully assembled condition (outer case fitted).
It is difficult to measure the exact temperature in the convection oven. An accurate thermocouple type temperature tester must be used. A low priced
bi-metal type thermometer is not reliable or accurate. Position the thermocouple in the center of the oven cavity. The temperature should be checked
with outer case cabinet installed and set the oven temperature to 250°C in the convection mode (Oven). Approx. 15 minutes after the oven is started,
the temperature experienced may be approx. 15°C more or less than set temperature, however, in most cases the food cooking results will be satis-
factory. Difference in power supply voltage will also affect the oven temperature. The Household power supply voltage may sometimes become lower
than the rated voltage and cause under-cooking. If the power supply voltage is 10% lower than the rated voltage, longer cooking time is required by
10% to 20%.

[6] ERROR LIST

Error
EE
Detail of error
display
code
Oven temperature
U04
04
is high.
Water exist in the
U11
0B
water tank
U15
0F
Water tank is frozen
"
"
0A
Shortage of Water
blinking
Error
EE
Detail of error
dis-
code
play
C00
Matching error
C01
Thermister (Oven)
<=>
11
error
888
C02
Humidity sensor
<=>
12
error
888
C05
Engine heater
<=>
15
error
888
C07
Relay monitor
<=>
17
error
888
01(Ad
dress
Antenna error
05)
C12
Thermister
<=>
1C
(Engine) error
888
EEPROM error
C14
(EEPROM data
verification error)
Something is burn-
(reset)
ing in the oven.
EE code
EE code is memorized in the EEPROM address 04h as error history.
Only antenna error code is memorized in the EEPROM address 05h.
To check the EE code, carry out the test mode No.2 as follows.
Power on and door closed
Select test number 2 by encoder) [
Error condition
Oven temperature is too
high
Water exist in the water
tank at drain mode
Engine heater tempera-
ture is too low.
Water in the water tank
isn't enough.
Error condition
The control unit and/or display unit is not for this model.
Thermister (Oven) is short or
open.
Humidity sensor is short or
open.
Engine heater temperature is
too high.
error condition
microwave mode: when convection heater or engine heater
operate.
all relay is off: when convection heater or engine heater
operate both convection heater and engine heater operate.
Antenna motor or antenna switch does not work.
Thermister (Engine) is open.
EERROM Read data is not
same as EEPROM write data.
Humidity ladder level is too
low.
[
]
[
]
]
(Select address 04h or o5h by
Application
Check
menu
method
fermentation
Thermistor
defrost
(Oven)
Water level
drain mode
sensor
Steam mode
Thermister
water oven
(Oven)
water grill
Steam mode
Water level
water oven
sensor
water grill
Application menu
Oven mode
Grill mode
Microwave mode
(Humidity sensor menu)
Steam mode
Water oven
Water grill
Steam mode
Water oven
Water grill
PWB short check program
[
]
[Door open]
Version No. is displayed.
[
6 – 4
Check timing
from heating
start
"
" is blinking in the display.
After 1sec.
When oven temperature is turned
under 90C, error is released.
After 1sec
immediately
Auto mode:
after 30 sec
manual mode:
within 7 sec
Check timing
Plug in
Immediately
After 16 sec
Always
Microwave mode:
immediately
Oven, Grill mode:
when heater is off
When antenna error
is detected,
Microwave mode
outout of miccrowave
is stopped.
When engine heater
operates
more than 30sec.
Short check program
Plug in
After 7 min
])
Note
Note

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax-gx2t(w)

Table of Contents