[5] CHECKING TEMPERATURE IN THE CONVECTION (Oven) MODE

The following test procedure should be carried out with the oven is a fully assembled condition (outer case fitted).
It is difficult to measure the exact temperature in the convection oven. An accurate thermocouple type temperature tester must be used. A low priced
bi-metal type thermometer is not reliable or accurate. Position the thermocouple in the center of the oven cavity. The temperature should be checked
with outer case cabinet installed and set the oven temperature to 250°C in the convection mode (Oven). Approx. 15 minutes after the oven is started,
the temperature experienced may be approx. 15°C more or less than set temperature, however, in most cases the food cooking results will be satis-
factory. Difference in power supply voltage will also affect the oven temperature. The Household power supply voltage may sometimes become lower
than the rated voltage and cause under-cooking. If the power supply voltage is 10% lower than the rated voltage, longer cooking time is required by
10% to 20%.

[6] ERROR LIST

Display
Detail of error
Wait. Oven is too
Oven tempera-
warm to use.
ture is high.
Drip tray isn't
Replace drip tray.
set.
Water in the drip
Empty drip tray
tray is not
and replace.
removed.
Remove water
Water exist in
tank.
the water tank.
Water is frozen.
Please refer to
Water tank is fro-
instructions in
zen.
operation manual.
Fill water tank with
Shortage of
water.
water.
SENSOR ERROR
Finish cooking by
AH sensor
time.
sequence error
Press CLEAR.
Display
EE01
Please refer to instructions in oper-
ation manual.
EE02
Please refer to instructions in oper-
ation manual.
EE05
Please refer to instructions in oper-
ation manual.
EE12
Please refer to instructions in oper-
ation manual.
EE14
Please refer to instructions in oper-
ation manual.
(reset)
Error condition
Application mode
Oven temperature is too
Proof defrost
high.
Drip tray isn't set.
Always
Drip tray is not removed
Steam mode
on repeatedly operation
super steam con-
of application mode.
vection
Water exist in the water
Drain mode
tank at drain mode.
Steam mode
Engine heater tempera-
super steam con-
ture is too low.
vection
Steam mode
Water in the water tank
super steam con-
isn't enough.
vection
Sensor stop error
caused by open door.
Sensor stop error
caused by pressing
microwave mode
Clear key.
(AH sensor menu)
Sensor does not detect
vapor or sensor circuit
error.
Detail of error
Oven thermister is short or
Oven thermister error
open.
AH sensor error
AH sensor is short or open.
Engine heater temperature is
Engine heater error
too high.
Engine thermister error
Engine thermister is open.
EEPROM error
EERROM Read data is not
(EEPROM data verifica-
same as EEPROM write data.
tion error)
Something is burring in
Oven thermister change level
the oven.
is abnormal.
Check method
Oven thermister
Dew tray switch
water level sensor
Dew tray switch
Water level sen-
sor
Oven thermister
water level sensor
AH sensor door
switch
Error condition
always
microwave mode (AH
sensor menu)
Steam mode
Super steam convection
Steam mode
Super steam convection
PWB short check pro-
gram
micro mode
6 – 4
AX1500J(S)
Check timing
from heating start
When oven
temperature is
After 1 sec.
turned under
90C error is
released.
Always except
heating
Immediately
After 1sec
Immediately
Auto mode:
after 30 sec.
Manual mode:
within 7 sec.
Always
Check timing from
Application mode
heating start
Immediately and
always
After 32 sec.
Always
When engine heater
operate more than
30sec.
short check program
After 5 min.
Note