Sharp AX-GX2T(R) Service Manual page 24

Table of Contents

Advertisement

3. How to check sensor (oven thermistor) performance
Power ON the main body.
Set the test mode to 03.
Press the START key.
Does a measured value for the oven thermistor change as oven heating proceeds?
Is the measured value within ±10 bits with respect to the
reference value after about eight (8) minutes?
Press the [
4. C01 Oven thermistor failure
Is the connector between the oven thermistor and board either disconnected or shorted?
Measure the oven thermistor resistance using a tester with the thermistor connecting
The oven thermistor resistance is within its appropriate range.
Replace the control unit or the display unit.
I Before starting the P.W.B. unit replacement, make sure to refer to "Before replacing the Printed Wiring Board" in page 2-2.
5. C02 Humidity sensor failure
Has the humidity sensor connector been disconnected from the control board?
Measure element resistance between the opened and sealed sides of the humid-
ity sensor with the humidity sensor connector disconnected from the board.
Normal resistance of the humidity sensor:
I Before starting the P.W.B. unit replacement, make sure to refer to "Before replacing the Printed Wiring Board" in page 2-2.
(See How to set test mode on page 6-5)
YES
YES
] key to finish the operation. (This action is required when everything is OK.)
NO
connector pulled out of the board.
YES
Note1
NO
NO
NO
C01: Proceed to checking the oven thermistor for failure.
YES
NO
Replace the oven thermistor or the harness.
Note 1. If the display unit is replaced,
carry out "
(citrate washing)".
YES
Connect the connector.
Is the resistance 0?
Is the resistance infinite?
Is the resistance normal?
Replace the control board.
6 – 7
Connect or repair the connector.
YES
Replace the humidity sensor.
NO
YES
Replace the humidity sensor.
NO
NO
Replace the humidity sensor.
YES