Temperature Table Compact Version - Endress+Hauser Proline Promag 53 Safety Instructions

Hart, profibus dp/pa, foundation fieldbus, modbus rs485 nepsi zone 1, zone 21
Hide thumbs Also See for Proline Promag 53:
Table of Contents

Advertisement

0
NEPSI Zone 1, Zone 21
Temperature table
compact version
6
Type (compact/remote; Item No. 13 in type code)
*
Type
A, P, U
Compact
V, 6
G, N, T, W
Remote
7, 8
Type of cable entry (Item No. 15 in type code)
*
Thread form
A
M20 × 1.5
B
NPT ½"
C
G ½"
Display, operation, power supply (Item No. 16 in type code)
*
A, C, E, G, P, R, 0, 2, 4, 7
B, D, F, H, Q, S, 1, 3, 5, 8
Outputs/inputs (Item No. 18 in type code)
*
A, B, C, D, J, K, L, M, N, P, Q, V, 2, 4, 5, 7
F, G, S, T
!
Note!
A detailed explanation of these values, regarding the available outputs and inputs, as well as a description of
the associated terminal assignments and connection data can be found from Page 11 onwards.
Max. medium temperature [°C] for T1
Promag 5*W**-************
1)
2)
with polyurethane lining;
with hard rubber lining
Promag 5*P**-************
1)
2)
with PFA lining;
with PTFE lining
Promag 5*H**-************
The minimum ambient temperature is –20 °C.
A version for ambient temperatures up to –40 °C is optionally available
Thread form
85 – 260 V AC
20 – 55 V AC/16 – 62 V DC
Type of protection
non Ex ia (intrinsically safe) input /output
Ex ia (intrinsically safe) input /output
~
T6 in relation to the maximum ambient temperature T
T6
DN
T
a
(85 °C)
1)
25 to 1200
+50 °C
50
2)
50 to 2000
+50 °C
80
T6
DN
T
a
(85 °C)
1)
25 to 200
+40 °C
80
2)
15 to 600
1)
25 to 200
+45 °C
80
2)
15 to 600
1)
25 to 200
+50 °C
80
2)
15 to 600
T6
DN
T
a
(85 °C)
+40 °C
80
2 to 150
+45 °C
80
+50 °C
80
Proline Promag 53
Min. ambient temperature T
–20 °C
–40 °C
–20 °C
–40 °C
T5
T4
T3
(100 °C)
(135 °C)
(200 °C)
(300 °C)
50
50
50
80
80
80
T5
T4
T3
(100 °C)
(135 °C)
(200 °C)
(300 °C)
150
95
130
130
95
130
130
95
95
95
T5
T4
T3
(100 °C)
(135 °C)
(200 °C)
(300 °C)
95
130
150
95
130
130
95
95
95
Endress+Hauser
a min
a
T2
T1
(450 °C)
50
50
80
80
T2
T1
(450 °C)
150
150
130
130
130
130
95
95
T2
T1
(450 °C)
150
150
130
130
95
95