  • Page 1 OPERATING MANUAL Submersible motor pump Magnum S...
  • Page 2 We should also like to emphasise that the contents of this operating manual do neither form part of nor alter in any way any previous or existing agreement, promise or legal relationship. Commitments on the part of BAUER are based solely on the respective purchase contract, which also contains the complete and only valid warranty arrangement.
  • Page 3 In all warranty claims and correspondence relating to this machine it is essential to specify the complete serial number group including all letters. This applies to the machine itself and to any components involved. We cannot emphasise this point often enough. Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 4: General Safety Instructions

     Intended use also includes compliance with the manufacturer’s operating, maintenance and service instructions.  The BAUER submersible motor pump may be used and operated only by persons who are familiar with the device and aware of the hazards involved.
  • Page 5: Table Of Contents

      4.3.7 Malfunction ............................15     4.3.8 Safety instructions ..........................15     SERVICE AND MAINTENANCE ........................16     TECHNICAL DATA ............................16     CONFORMITY CERTIFICATE ........................19 Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 6: General Instructions For Safety And Accident Prevention

    6. When driving on the road with the machine lifted the control lever must be locked against lowering! Trailed machines 1. When a machine is coupled to the drawbar make sure that the coupling point provides sufficient flexibility! Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 7 8. Never use electric-driven implements in damp situations or locations exposed to fire hazard unless they are adequately protected against moisture and dust! 9. Covering electric motors may cause heat concentration with high temperatures which could destroy the operating equipment and cause fires! Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 8: General

    2 GENERAL BAUER products are designed and manufactured carefully and subject to a system of continuous quality control. MAGNUM slurry pumps fully meet the requirements of the agricultural practice. They are best suited for delivering all kinds of slurries from thin liquid manure to viscous mixtures containing solids such as straw, fibres or clots.
  • Page 9: Description

    3 DESCRIPTION The submersible motor pump MAGNUM S consists of a three-phase submersible motor with connecting cable, and oil chamber, and the pump housing with cutter and impeller. The electric motor flanged onto the pump housing has a motor output of 4 / 5.5 / 7.5 / 11 or 15 kW, depending on the respective model.
  • Page 10: Manual Operation

    (Lowering the pump idle can cause blockages – forming of clots). 4.1 Manual operation 4.1.1 Control box components Three contactors with timer for start-delta start-up. Motor protection devices:  Current monitoring relay  Thermistor tripping relay for temperature monitoring Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 11: Controls

    018 2565.4 automatic reset 4.1.5 Operation  Push the green pushbutton: the motor starts up and changes automatically from “star” to “delta” after about 3 seconds . The green pushbutton is illuminated. Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 12: Malfunction

    Automatic mode, the motor is controlled by means of the float switch. Green pushbutton for starting the motor in manual and automatic mode. Red pushbutton for stopping the motor in manual mode. Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 13: Connections

    4.3.1 Control box components Three contactors with timer for star-delta start-up. Motor protection devices :  Overcurrent monitoring relay  Thermistor tripping relay for temperature monitoring Impulse-rest relay for intermittent operation Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 14: Controls

    5. Set the date, repeat steps 2 and 3 6. Finish the task: key OK 2.WEEKLY TIMER and INTERVAL parameter setting Parameter blocks: B09 Interval parameter B11 Weekly timer parameter B17 Operating hours meter value Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 15: Malfunction

    Check control power fuse “F3“. 4.3.8 Safety instructions Always disconnect system from power before working on the starter. WARNING! In the automatic mode the motor starts up without a warning! Mount a safety sign! Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 16: Service And Maintenance

    7,4 - 11,3 8 - 11,4 Oil capacity 3,5 l motor oil- SAE 20 W-20 (SAE HD 30) Engine Oil; Viscosity Grade SAE20W20 or SAE20; SAE HD30; Quality Level API CF/SF Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 17 In manual mode the red pushbutton goes out. In level and intermittent operation turn the mode selector to “0”, then the red pushbutton goes out and the alarm horn stops Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 18 PTC thermistor Submersible Motor Pump 22.06.01 Gw Wiring diagram: 345 9900.4 Röhren- u. Pumpenwerk BAUER GmbH 8570 Voitsberg Operating manual BAUER Submersible Motor Pump / Version X-2010...
  • Page 19: Conformity Certificate

    The documents belonging to the machine according to annex VII, part B have been attached. Person in charge of documentation: Thomas Theissl, Kowaldstraße 2, 8570 Voitsberg, Austria, Technical Designer in Charge Commercial Manager Operating manual BAUER Submersible Motor Pump / Version X-2010...