Manual Operation; Control Box Components - Bauer Magnum S Operating Manual

Submersible motor pump
Table of Contents

Advertisement

In case of heavy oil loss or if the oil is soiled with slurry, the mechanical seal must be inspected. Check if
the pump is soiled or if foreign objects are in the pump. If necessary, rinse and clean it.

4.1 Manual operation

4.1.1 Control box components

Three contactors with timer for start-delta start-up.
Motor protection devices:
Current monitoring relay
Thermistor tripping relay for temperature monitoring
Operating manual BAUER Submersible Motor Pump / Version X-2010
 Place the pump in vertical position.
 Open level inspection screw.
 Oil level must be up to the opening.
Break up the floating crust and lower the running pump.
(Lowering the pump idle can cause blockages – forming
of clots).
10

Advertisement

Table of Contents
loading

Table of Contents