Malfunction; Safety Instructions - Bauer Magnum S Operating Manual

Submersible motor pump
Table of Contents

Advertisement

In order to get access to the mode parameter, press the key ESC -> LOGO changes to the mode
parameter and displays the parameter menue.
Choose „SET PARAM" key AB and OK.
1. In order to change a parameter, choose one parameter
2. Put the cursor to the position you want to change: keys RIGHT or LEFT.
3. Change the value at the position: keys UP or DOWN
Change value: key
4. Confirm value with the key OK.
Weekly timer:
1.1.1 Current time of timer
Time of the interval TH = exposure time TL = time of break (if the timer is active)
Meter for hours of operation: Display of the expired hours of operation

4.3.7 Malfunction

The red pushbutton is alight: The motor protection has switched off the motor.
Motor cannot be started:

4.3.8 Safety instructions

Always disconnect system from power before working on the starter.
WARNING!
Operating manual BAUER Submersible Motor Pump / Version X-2010
Move: key
or
Finished: key OK
or
The status of the timer is displayed
Timer OFF
(Status 0 at the exit)
timer ON
(Status 1 at the exit)
Parameter
The set value of the parameter
Effective value of time in LOGO!
Eliminate the cause of the fault.
Turn selector to "0", the red pushbutton goes out and the alarm horn stops.
Check power supply.
Check control power fuse "F3".
In the automatic mode the motor starts up without a warning!
Mount a safety sign!
The status of the timer depends on all three cams
No1, No2 and No3.