  • Page 1 OPERATING MANUAL Long Shaft Pump Magnum LP / LE...
  • Page 2 Thank you very much for purchasing a BAUER Long Shaft Pump! We have pleasure to present to you a BAUER long shaft pump that features state-of-art technology and top quality. This manual describes how to operate and maintain your BAUER long shaft pump. For reasons of clearness and due to the many possibilities, this manual does not contain everything down into detail.
  • Page 3 In all warranty claims and correspondence relating to this machine it is essential to specify the complete serial number group including all letters. This applies to the machine itself and to any components involved. We cannot emphasise this point often enough. Operating Manual for BAUER Long Shaft Pump...
  • Page 4 • Intended use also includes compliance with the manufacturer’s operating, maintenance and service instructions. • The BAUER long shaft pump may be used and operated only by persons who are familiar with the device and aware of the hazards involved.
  • Page 5: Table Of Contents

    SETTING UP WITH THE LIFT POLE ........................12 SETTING UP WITH THE SUPPORT FOR PIT EDGE..................14 PUTTING INTO OPERATION..........................14 STIRRING WITH STIRRING NOZZLE ........................14 PUMPS ..................................15 SERVICE AND MAINTENANCE ........................16 TECHNICAL DATA..............................17 FAULT DESCRIPTION ............................18 EU CONFORMITY CERTIFICATE........................19 Operating Manual for BAUER Long Shaft Pump...
  • Page 6: General Instructions For Safety And Accident Prevention

    5. When the machine is in the transport position always make sure that the tractor’s links are always properly secured on the sides. When driving on the road with the machine lifted the control lever must be locked against lowering! Operating Manual for BAUER Long Shaft Pump...
  • Page 7 8. Never use electric-driven implements in damp situations or locations exposed to fire hazard unless they are adequately protected against moisture and dust! 9. Covering electric motors may cause heat concentration with high temperatures which could destroy the operating equipment and cause fires! Operating Manual for BAUER Long Shaft Pump...
  • Page 8 7. Before electric welding on the tractor and mounted machines the generator and battery cables must be disconnected! 8. Spare parts must meet manufacturer’s minimum technical specifications! This is the case for instance with original spare parts for instance! Operating Manual for BAUER Long Shaft Pump...
  • Page 9: General

    2 GENERAL BAUER products are designed and manufactured carefully and subject to a system of continuous quality control. MAGNUM slurry pumps fully meet the requirements of the agricultural practice. They are best suited for delivering all kinds of slurries from thin liquid manure to viscous mixtures containing solids such as straw, fibres or clots.
  • Page 10: Description

    For transport reasons the pump and the lift pole are delivered separately. Both components therefor have to be assembled before putting into operation for the first time. Detach the guiding clamps from the pump support. Operating Manual for BAUER Long Shaft Pump...
  • Page 11 If the locking lever is lifted or not engaged, move the pump with the cable winch until it rests in the gap ... The pump is now ready for operation. Operating Manual for BAUER Long Shaft Pump...
  • Page 12: Transport

    (secure with the split pin) hook in the tool bar directly below the two hooks. 6 Setting up with the lift pole Approach the pit/ pit opening with the pump at the rear. Operating Manual for BAUER Long Shaft Pump...
  • Page 13 Set the pump on the lift pole. By lifting the locking lever of the drive shaft, the height of the pump can be adjusted. Operating Manual for BAUER Long Shaft Pump...
  • Page 14: Setting Up With The Support For Pit Edge

    If you have slurry with a strong bottom layer or sediment (e.g. pig slurry) the pump has to be lowered further. The stirring procedure should be conducted until the slurry is completely homogenized. Operating Manual for BAUER Long Shaft Pump...
  • Page 15: Pumps

    Warning: After coupling the tractor PTO shaft, only gradually increase the speed of rotation so that the pressure line does not pressure hammer because of the sudden pressure. While distributing the slurry, under normal conditions, it is only necessary to briefly mix every 3 hours. Operating Manual for BAUER Long Shaft Pump...
  • Page 16: Service And Maintenance

    800 to 1000 operating hours. All other bearings and sliding parts also at the lifting pole should be lubricated on a regular basis. Operating Manual for BAUER Long Shaft Pump...
  • Page 17: Technical Data

    Liter The technical data, pcitures and measurements are not binding. They cannot be the basis for claims. We reserve the right to modify the equipment without making corrections to the present instruction manual Operating Manual for BAUER Long Shaft Pump...
  • Page 18: Fault Description

    Reverse direction of rotation. Shear pin at the PTO shaft broken Replace shear pin (LP) Excessive solids content. Add water The discharge capacity drops. Excessive counter pressure. Remove foreign object. Excessive solids content. Add water Operating Manual for BAUER Long Shaft Pump...
  • Page 19: Eu Conformity Certificate