Coax Connector (1.6/5.6 - Alcatel-Lucent 1645 AMC Installation Manual

Access multiplexer compact amc
Hide thumbs Also See for 1645 AMC:
Table of Contents

Advertisement

Cable assembly instructions
...................................................................................................................................................................................................................................

Coax connector (1.6/5.6)

Description
There are the following type of connectors:
• IMS — type 3320.52.1420.0D5 (45°)
• IMS — type 2630.52.1310.0D5 (Straight)
IMS
Important! Use of the correct tools to ensure a proper connection.
Proceed as follows to assemble a coax 1.6/5.6 connector:
...................................................................................................................................................................................................
1
Strip the cable according to the dimensions indicated in the next figure and tin the center
conductor.
Important! The stripping lengths depend on the used connector type.
...................................................................................................................................................................................................
2
Pull the crimp outer ferrule over the stripped cable.
...................................................................................................................................................................................................
Pull back the cable braid.
3
...................................................................................................................................................................................................
Push the center conductor and the dielectric into the connector housing until the dielectric
4
stops.
...................................................................................................................................................................................................
Solder the inner conductor to the center contact of the connector housing.
5
...................................................................................................................................................................................................
6
After soldering, press the cover into the connector body.
...................................................................................................................................................................................................
First roll the cable braid over the termination part (inner ferrule) of the connector and pull
7
the crimp outer ferrule over that braid.
...................................................................................................................................................................................................
Crimp the outer ferrule with a hexagon die 4.6 — AGK 3068 by using the Crimp Tool —
8
AGK 2365.
E
N D
O F
...................................................................................................................................................................................................
...................................................................................................................................................................................................................................
365-313-103R8.0
Issue 2 July 2009
S T E P S
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Coax connector (1.6/5.6)