B. Choose "kg" as the weight unit for the weight calibration
• The first weight unit setting: 6.000 kg / 0.002 kg
⇒ Enter the maximum capacity 006000 at (c) ~ (h)
⇒ Enter the mass value 006000 at (i) ~ (n)
‚ The second weight unit setting "lb/oz" (hexadecimal notation system):
0.001 kg = 0.002204623 lb
6 kg = 6×2.204623 (lb) = 13.227738 lb. Take 12 lb as the max capacity
12._0.00 lb / 0.08 oz (minimum division=8, decimal point position=2)
12 lb ×16 (oz) = 192.00 oz
13.227738 lb ×16 (oz) = 211.64 oz ⇒ Enter the mass value 021164 at (i) ~ (n)
PW Service Manual
⇒ Enter the maximum capacity 019200 at (c) ~ (h)