c
After the power I/O button is pressed once, the relay and AC SWITCH are turned on or
off per the remote control setpoint.
– AC SWITCH U9 is controlled per the fan speed selection.
– Relay K1 is controlled per the operation mode selection.
If the power I/O button is pressed once more, the relay and AC SWITCH are turned off
and the unit stops operation.
The unit turns on or off according to the temperature setpoint by sensing the room air
temperature through thermistor.
If the fan speed selection is set to the auto position, the fan speed is automatically
controlled according to the temperature difference between room temperature and
temperature setpoint.