Carrier 42HQE009 Installation Manual
Hide thumbs Also See for 42HQE009:

Advertisement

42HQE009/012/018/022
38YE009/012/018/022
INSTALLATION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 42HQE009 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier 42HQE009

  • Page 1 42HQE009/012/018/022 38YE009/012/018/022 INSTALLATION MANUAL...
  • Page 2: Table Of Contents

    42HQE009/012/018/022-38YE009/012/018/022 Split system “Hi-Wall” indoor and outdoor units For operation and maintenance instructions of this unit as well as installation instructions, refer to owner’s manuals. Contents Page General information ..................Parts Installation ..................Indoor unit installation................. Drilling a hole and mounting installation plate ........
  • Page 3: General Information

    42HQE009/012/018/022-38YE009/012/018/022 General information Unit installation IMPORTANT: • For correct installation, read this manual before starting • Restrictions to connection may be imposed by the supply authority installation. on the use of equipment if the actual system impedance at the • Only trained and qualified service personnel should install, repair interface point on the user’s premises exceeds 0.115 ohms for...
  • Page 4: Parts Installation

    42HQE009/012/018/022-38YE009/012/018/022 Parts Installation E N G L I S H Part No Name of part Q’ty 009 - 012, 018 - 022 Installation plate Mounting screw A ST3.9x25-C-H Clip anchor Mounting screw B ST2.9x10-C-H Refrigerant pipe Liquid side Ø 6.35 Ø...
  • Page 5: Indoor Unit Installation

    42HQE009/012/018/022-38YE009/012/018/022 Indoor unit installation Drilling a hole and mounting installation plate Connective Pipe and Drainage Installation Installation Plate and Its Dimension (mm) Drainage 1. Run the drain hose sloping downward. Do not install the drain hose as illustrated below. ³ Do not form a rise ·...
  • Page 6: Dimensions And Minimum Clearance

    42HQE009/012/018/022-38YE009/012/018/022 Indoor unit installation E N G L I S H Dimensions and Minimum clearances (mm) 90 min. min. min. 2000 min. Obstacle Model 42HQE009 42HQE012 42HQE018 42HQE022 A mm 1080 B mm C mm Upper hooker Low hooker Cushioning material 1.
  • Page 7: Wiring Connection

    42HQE009/012/018/022-38YE009/012/018/022 Indoor unit installation Wiring connection Connecting Cables 1. Indoor/Outdoor connection cable should be H07RN-F5G type. Prepare the power source for exclusive with the air conditioner. The supply voltage must comply with the rated voltage of the air 2. Remove the panel and remove the screw of electric cover, then conditioner: The plug socket shall be accessible after installation.
  • Page 8: Outdoor Unit Installation

    42HQE009/012/018/022-38YE009/012/018/022 Outdoor unit installation E N G L I S H Minimum clearances (mm) Mod. 38YE009/012 38YE018/022 A mm 100 mm or more 100 mm or more B mm 100 mm or more 100 mm or more C mm 600 mm or more...
  • Page 9: Refrigerant Piping Connection

    42HQE009/012/018/022-38YE009/012/018/022 Outdoor unit installation Wiring connection Refrigerant piping connection 1. Remove the electric parts cover from the outdoor unit. Flaring 2. Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of 90°C...
  • Page 10: Air Purge

    42HQE009/012/018/022-38YE009/012/018/022 Air purge and test operation E N G L I S H Air purge ¸ ¸ Manifold valve ¹ Compound meter Choose purge method from the table: ¹ -76cmHg Models Connective Additional amount Air purging Pressure gauge pipe length...
  • Page 11 42HQE/38YE (IOM) Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - Tel. 039/3636.1 The manufacturer reserves the right to change any product specifications without notice. December, 2004.