Advertisement

42HQE009(012)/38YE009(012)
R-407C
MANUAL DE INSTALACION
GB
INSTALLATION MANUAL
E
I
MANUALE DI INSTALLAZIONE
ÏÄÇÃÉÅÓ ÅÃÊÁÔÁÓÔÁÓÇÓ
GR
MANUEL D INSTALLATION
F
S
INSTALLATIONSMANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 42HQE009(012)

  • Page 1 42HQE009(012)/38YE009(012) R-407C MANUAL DE INSTALACION INSTALLATION MANUAL MANUALE DI INSTALLAZIONE ÏÄÇÃÉÅÓ ÅÃÊÁÔÁÓÔÁÓÇÓ MANUEL D INSTALLATION INSTALLATIONSMANUAL...
  • Page 2 42HQE009(012)/38YE009(012) ENGLISH Split system Hi-Wall indoor unit ITALIANO Climatizzatori split unit interna Hi-Wall FRANCAIS Climatiseur split unit int rieure Hi-Wall ESPANOL Acondlclonador de aire split unidad interlor Hi-Wall ÅËËÇNIÊÁ Äéáéñïõìåíåó êëéìáôéóôéêåó óõóêåõåó å éôïé÷åó ð SVENSKA Split system Hi-Wall inomhusenhet...
  • Page 3: Installation Precaution

    42HQE009(012)/38YE009(012) For correct installation, read this manual before starting installation. Only trained and qualified service personnel should install, repair or service air conditioning equipment. Users should not install the air conditioner by themselves. All pictures are only sketches. If there is any difference between pictures in this manual and the actual shape of the air conditioner you purchased, the actual shape shall prevail.
  • Page 4 42HQE009(012)/38YE009(012) Restrictions to connection may be imposed by the supply authority on the use of equipment if the actual system impedance at the interface point on the user s premises exceeds 0.12ohm The unit complies with low-voltage (EEC/73/23) and electromagnetic compatibility (EEC/89/336) directives.
  • Page 5: Parts Installation

    42HQE009(012)/38YE009(012) ENGLISH Parts Installation Part Cautions on remote controller installation Name of part Q ty Before installation, operate the remote Installation plate controller to determine its location in a Mounting screw ST3.9 25-C-H reception range. Clip anchor Keep the remote controller at least 1m Liquid side 6.35 Refrigerant...
  • Page 6: Indoor Unit Installation

    42HQE009(012)/38YE009(012) INDOOR UNIT INSTALLATION 1. Drilling A Hole and Mounting Installation Plate Installation Plate and Its Dimension 1. Fix the installation plate. Indoor unit outline Installation plate 15cm or more to ceiling 1. Install the installation plate horizontally on structural parts in the wall with the spaces 12cm or more 12cm or more provided around the plate.
  • Page 7: Connective Pipe And Drainage Installation

    42HQE009(012)/38YE009(012) ENGLISH 2. Connective Pipe and Drainage Installation 2. Connective pipe 1. Drainage 1. Run the drain hose sloping downward. Do Pipe holder Pipe cover not install the drain hose as illustrated Left piping below. Pipe cover Left back piping Right back piping Right piping 1.
  • Page 8 42HQE009(012)/38YE009(012) 3. Indoor Unit Installation 1. Pass the piping through the hole in the wall. 2. Put the upper claw at the back of the indoor unit on Upper hooker the upper hook of the installation plate, move the indoor unit from side to side to see that it is securely hooked.
  • Page 9: Connecting Cables

    42HQE009(012)/38YE009(012) ENGLISH 4. Wiring Prepare the power source for exclusive with the air conditioner. The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation. Plug socket and Fuse rating Wiring Model Power Source...
  • Page 10: Outdoor Installation Precaution

    42HQE009(012)/38YE009(012) OURDOOR UNIT INSTALLATION 1. OUTDOOR INSTALLATION PRECAUTION Install the outdoor unit on a rigid base to prevent increasing noise level and vibration. Determine the air outlet direction where the discharged air is not blocked. In the case that the installation place is exposed to strong wind such as a seaside operation by putting the unit lengthwise along the wall or using a dust or shield plates.
  • Page 11: Refrigerant Piping Connection

    42HQE009(012)/38YE009(012) ENGLISH 3. REFRIGERANT PIPING CONNECTION 1. Flaring 2. Tightening Connection Align pipes to be connected. 1. Cut a pipe with a pipe cutter. Sufficiently tighten the flare nut with fingers, and then tighten it with a spanner and torque 90 C Oblique Roughness...
  • Page 12: Air Purge

    42HQE009(012)/38YE009(012) AIR PURGE AND TEST OPERATION When Using the Vacuum Pump 1. AIR PURGE (For method of using a manifold valve, refer to its operation manual.) Choose purge method from the table: 1. Completely tighten the flare nuts, A, B, C, D, connect the manifold valve charge hose to a charge port of the packed valve on the gas Additional amount of Connective...
  • Page 13 Via R.Sanzio,9-20058 Villasanta (MI) italy-Tel.039/3636.1 The manufacturer reserves the right to change any product specifications without notice. La cura costante per il miglioramento del prodotto pu comportare senza preavviso,cambiamenti o modifiche a quanto descritto. La recherche permanente de perfectionnement du produit peut n cessiter des modifications ou changements,sans pr avis. El fabricante se reserva el derecho de cambiar algunas especificaciones de los productos sin previl aviso.

This manual is also suitable for:

38ye009(012)