– The life time of optional Active carbon filter is about 2 years and that of optional
Electrostatic filter is about 3 months.(In case of electrostatic filter, refer to color
sample sticker indicating pollution level.)
These filters cannot be recycled.
– The life time of optional Photo-catalyst filter is about 2 years. This filter can be
washed under running water and can be refreshed by exposing under direct sun
light. Exposed time is 6 hours after using 3 months.
– When you need new filters, call your distributor.
• STEP 1
– Remove the two air filters
• STEP 3
– Insert active carbon and electrostatic filter
(or photo-catalyst filter) into each other
frame collector.
four hooks
hook holder
NOTE
• Do not keep the filters unpacked, before inserted into the unit. The life of the filters may be reduced.
• Do not splash water into the active carbon filter, as the life and capability of the filters may be reduced.
• The operation with filter may reduce a little air flow and capacity of the unit.
• The active carbon filter should be inserted into left.
Electrostatic filter
or
photo-catalyst filter
Active carbon filter
28
• STEP 2
– Pull out the two collectors.
• STEP 4
– Refix the air filters and close the insert grille.
Time to replace