Philips DVDR9000H/75 Service Manual page 121

Hdd & dvd recorder
Table of Contents

Advertisement

Firmware Upgrading & Diagnostic Software
Nucleus Name
DS_DTTM_ AvVideoStandardSet
Nucleus Number
2228
Description
Configures the Mojo video channel to the given video standard.
Technical
- Send the DTTM command ID 1501, together with supplied input value.
Execution Time
< 1 sec.
User Input
VideoStandard: Video standard to set the channel to
Error
Number
222800
222801
222802
222803
222804
222805
Example
DS:> 2228
222800:
Test OK @
Nucleus Name
DS_DTTM_ AvVideoOutputSet
Nucleus Number
2229
Description
Configures the video output to the selected video standard.
Technical
- Send the DTTM command ID 1504, together with supplied input values.
Execution Time
< 1 sec.
User Input
1. VideoDAC : The video DAC to configure
2. VideoOutput: The video output to set the DAC's to
Error
Number
222900
222901
222902
222903
222904
222905
Example
DS:> 2229 0 1
222900:
Test OK @
Nucleus Name
DS_DTTM_FreRegisterRead
Nucleus Number
2230
Description
Reads a single byte of data out of a demodulator register.
Technical
- Send the DTTM command ID 3601, together with supplied input value.
Execution Time
< 1 sec.
User Input
Address: register address to read from
Error
Number
223000
223001
223002
223003
223004
223005
Example
DS:> 2230 0x12
223000: The value of this register: 0x00
Test OK @
Description
Succeeded in configuring the Mojo video channel
Insufficient number of input data supplied
Non-existent video standard
Configuring the Mojo video channel was not successful
Communication with the DTT Module failed.
DTT Module initialisation failed.
0
0 = RGB / YUV / YC (TV DAC's)
1 = CVBS / Y (TV DAC)
2 = YC / CVBS (VCR DAC's)
0 = RGB or CVBS or YC (resp. the chosen DAC's)
1 = YUV or YC or CVBS
2 = YC
Description
Video output could be set successfully
Insufficient number of input data supplied
One of the parameter values is out of range
Video output could not be set
Communication with the DTT Module failed
DTT Module initialisation failed.
Description
The selected address register could be read successfully
Insufficient number of input data supplied
The register address value is out-of-range
The selected address register could not be read
Communication with the DTT Module failed
DTT Module initialisation failed.
3139 785 31681
(0=PAL, 1=SECAM)
5.
EN 121

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvdr9000h/10Dvdr9000h/97

Table of Contents