(6) Download the SEL to the operation terminal. See Appendix E.8
(7) Unzip the "SystemEventLog.zip" then copy "config.txt" file onto desktop of the operation terminal.
(8) Open the "config.txt" with text editor.
A slot with (Install) indicates that the slot is populated, and (
(9) Confirm that installed DU_SAS is displayed as "Install". (See "Figure 6.4-2".)
(10) Confirm RAID Controller and HDD/SSD is displayed as "Install". (See "Figure 6.4-2".)
(11) Confirm the HDD or SSD same as the system administrator instructions.
(12) When FBU (BBU) option is installed, confirmation of FBU (BBU) status is necessary.
See Appendix E.10
(13) Make sure that orange indicator of the "System Alarm" and "CSS" are not lit or blinking.
(See "Figure 6.4-3".)
Figure 6.4-1
Figure 6.4-2 Example
"FBU (BBU) status
confirming".
"SEL
) not populated.
49
downloading".