Download Print this page
Ruckus Wireless ZoneFlex 7782 Mounting Manual
Hide thumbs Also See for ZoneFlex 7782:

Advertisement

ZoneFlex 7782, 7782-N and
7782-S Access Point

Mounting Guide

CAUTION!
The minimum software revision for all 7782 APs is
ZoneFlex (ZF) 9.5.1 or SmartCell Gateway (SCG) 1.1.1 or later.
DO NOT CONNECT ANY 7782 AP TO A RUCKUS WIRELESS
CONTROLLER WITH ZF 9.5.0 OR SCG 1.1.0 OR EARLIER.
This Mounting Guide provides step-by-step instructions on how
to field-install the Ruckus Wireless ZoneFlex 7782 Omni (9x1-
7782-xx01), 7782-N 30-Degree Narrow Sector (9x1-7782-xx61),
and 7782-S 120-Degree Sector (9x1-7782-xx51) access point
(AP). Unless specifically indicated, the rest of this document refers
to the 7782, 7782-N and 7782-S access points as APs.
For detailed information on planning the installation, pointing the
internal GPS antenna, performing a site survey, preparing the AP
at the depot and shipping to the field, refer to the ZoneFlex 7782
Dual Band 802.11n Outdoor Access Point Installation Guide. For
information on operating the AP, refer to the ZoneFlex Outdoor
Access Point User Guide. Both documents are available at
https://support.ruckuswireless.com.
WARNING:
Only trained and qualified personnel should be
allowed to install, replace, or service this equipment.
WARNING:
Installation of this equipment must comply with local
and national electrical codes.
CAUTION:
Make sure that you form a 80mm - 130mm (3"-5")
drip loop in any cable that is attached to the AP or the building.
This will prevent water from running along the cable and entering
the AP or the building where the cable terminates.
CAUTION:
Be sure that grounding is available and that it meets
local and national electrical codes. For additional lightning
protection, use lightning rods and lightning arrestors.
CAUTION:
Make sure that proper lightning surge protection
precautions are taken according to local electrical code.
WARNING:
Ruckus Wireless strongly recommends that you wear
eye protection before mounting the AP.
Copyright © 2014 Ruckus Wireless, Inc.
Published June 09 2014, Part Number 800-70553-001 Rev D
B
Y
B
EFORE
OU
EGIN
Before deploying Ruckus Wireless products, please check for the
latest software and the release documentation.
User Guides and Release Notes are available at
http://support.ruckuswireless.com/documents
Software Upgrades are available at
http://support.ruckuswireless.com/software
Open Source information is available at
http://opensource.ruckuswireless.com
Software License and Limited Warranty available at
http://support.ruckuswireless.com/warranty
T
G
O
L
HIS
UIDE IN
THER
ANGUAGES
请从以下网站获得该指南的简体中文版
https://support.ruckuswireless.com.
Vous trouverez la version française de ce guide à l'adresse
suivante https://support.ruckuswireless.com.
こ の ガ イ ド の日本語版は
https://support.ruckuswireless.com
で ご 覧 く だ さ い。
이 가이드의 한국어 버전은 웹 사이트
(https://support.ruckuswireless.com) 에서 확인하시기 바랍니
다 .
Veja a versão em português (Brasil) deste guia em
https://support.ruckuswireless.com.
Puede ver la versión en español (América Latina) de esta guía
en
https://support.ruckuswireless.com.
P
C
ACKAGE
ONTENTS
Before deploying your AP in the field, verify that all items listed
below are included in the package. If any item is damaged or
missing, notify your authorized Ruckus Wireless sales
representative. Also, make sure that you have the required
hardware and tools.
One 7782, 7782-N or 7782-S AP (A in Figure 1); includes one
12mm stainless steel M6x1 earth ground screw with split lock
and flat washers
One AC power cable input end connector (B in Figure 1)
Two M25 data cable glands (C in Figure 1)
One green/yellow earth ground wire with ring terminal (D in
Figure 1)
One loop-and-eye safety cable (E in Figure 1)
One wall- or pole-mount hanger mount (F in Figure 1)
One extension bracket (G in Figure 1)
One AP mounting bracket (H in Figure 1)
Two sets 40mm stainless steel M8x1.25 hex bolt with split
lock and flat washers (I in Figure 1)
Four SAE32-sized stainless steel clamps, 1.5- to 2.5-inch
diameter (J in Figure 1)
Four sets 0.625-inch stainless steel 0.250-28 hex bolt with
split lock and flat washers (K in Figure 1)
Four sets 12mm stainless steel M4x0.7 Phillips pan-head
screws with split lock and flat washers L in Figure 1)
NOTE:
This kit may include extra screws, nuts and washers. You
may use the extras wherever required.
Figure 1:
AP field-installation package contents
A
A
B
B
C
D
E
I
J
K
The field installation package can also include:
Service Level Agreement/Limited Warranty Statement
Regulatory Statement
Registration card
Declaration of Conformity, if required
This Mounting Guide
R
H
T
EQUIRED
ARDWARE AND
OOLS
Torque wrench or torque screwdriver with sockets and bits
Long-nose pliers
Small and wide flat-blade screwdrivers
Electrical wire stripping and terminal crimping pliers
Customer-supplied outdoor-rated Cat5e UTP RJ-45 Ethernet
cable with 4.0mm to 6.5mm (0.17" to 0.26") round cable
sheath
If you are mounting the AP on a flat surface, then you will also
need:
Customer-supplied wall anchors with up to M6 or 0.25"
stainless steel screws rated to withstand 128 N or 28.8 lbf
(required to withstand wind loads of 266km/h or 165mph)
Electric drill with drill bits and customer-supplied wall anchors,
flat washers, and hex nuts for flat-surface mount
If you are mounting the AP on a pipe or pole, then you will also
need:
A 38mm to 63mm (1.5" to 2.5") pipe or pole
Four factory- or customer-supplied stainless steel clamps
F
G
H
L
Page 1 of 4

Advertisement

loading

Summary of Contents for Ruckus Wireless ZoneFlex 7782

  • Page 1: Mounting Guide

    Puede ver la versión en español (América Latina) de esta guía • This Mounting Guide at the depot and shipping to the field, refer to the ZoneFlex 7782 https://support.ruckuswireless.com. Dual Band 802.11n Outdoor Access Point Installation Guide. For information on operating the AP, refer to the ZoneFlex Outdoor...
  • Page 2 Step 4B: holes on the hanger mount as a template to mark the Dome-Down Mounting the locations of the mounting holes. Copyright © 2014 Ruckus Wireless, Inc. Page 2 of 4 Published June 09 2014, Part Number 800-70553-001 Rev D...
  • Page 3 Adjust the azimuth and elevation of the AP as required. Note hanger mount. the preferred internal GPS antenna position. Continue with Step 5: Earth Grounding the Copyright © 2014 Ruckus Wireless, Inc. Page 3 of 4 Published June 09 2014, Part Number 800-70553-001 Rev D...
  • Page 4 Your device must use any other address from 192.168.0.2 through 192.168.0.254, with subnet mask 255.255.255.0 and default gateway 192.168.0.1. The username is super, and the password is sp- admin. Refer to the ZoneFlex 7782 Dual Band 802.11n Outdoor Access Point Installation Guide and Earth Ground the ZoneFlex Outdoor Access Point User Guide for information on configuring and operating the AP.

This manual is also suitable for:

Zoneflex 7782-nZoneflex 7782-s