4-2-3

06 hex: Operation command (Resets the peak hold current)

This function resets the peak hold current.
Frame configurations
The frame configurations of ModbusTCP are as follows.
 Request
(1)
00
00
2
(1): Transaction ID
(2): Protocol ID
(3): Number of bytes transferred
(4): Unit ID
(5): Function code
(6): Start address
(7): Number of words to read
 Normal response
It is the same as the request.
 Error response
(1)
00
00
2
(3): Number of bytes transferred
(5): Function code
(10): Exception code
Note The elements shaded in the above figures are set to the value specified in the request.
Switch-mode Power Supplies Communications Manual (T213)
4 Monitoring and Setting with the Modbus TCP
(2)
(3)
00
00
00
06
2
2
: Specify any value. For example, 0000 hex is used in this explanation.
: Specify 0000 hex.
: Specify the total number of bytes of (4) and the successor. In the
above case, it is from (4) to (7), so it is 0006 hex.
: Specify FF hex.
: Specify 06 hex (Operation command).
: Specify 1000 hex (Resets the peak hold current).
: Specify 0001 hex (Reset).
(2)
(3)
00
00
00
03
2
2
: The total number of bytes of (4) and the successor is set.
: 86 hex is set.
: The error information is set. Refer to 4-2-5 Exception Code List on
page 4-7.
(4)
(5)
(6)
FF
06
10
00
1
1
2
(4)
(5)
(10)
FF
86
1
1
1
(7)
Hex
00
01
Bytes
2
4 - 5
4