3. Note the MAC address of the MultiNet unit. For this example, a MAC address of 00-20-4A-62-AE-
00 will be used. The MAC address is located on the rear of the unit.
4. Connect MultiNet to the network LAN. Consult your IT administrator to determine a suitable IP
address, subnet, and gateway setting for the unit. For this example we will use 192.168.1.2 as the
IP address, 255.255.255.0 as the Subnet and 192.168.1.1 as the Gateway.
5. Open the MultiNet setup software. Use the procedure detailed in the Configuration section to
configure the unit. For this example the following settings will be used:
Device Name: MultiNet 1
IP Address:
Subnet:
Gateway:
Baud Rate:
Parity Bit:
NOTE
6. Close the MultiNet setup software and open enerVista Viewpoint.
7. From the main screen of enerVista Viewpoint, click Device Setup to open the Device Setup
window.
8. On the left is the device list showing the "Quick Connect" default site. Click on the plus sign next
to the "Quick Connect" site to reveal the "Quick Connect" default device. Selecting this device
allows parameters to be entered in the right pane.
GE Digital Energy
Courtesy of NationalSwitchgear.com
192.168.1.2
255.255.255.0
192.168.1.1
19200
None
The baud rate and parity bit are identical to those set within the PQM. Additionally, the
MAC address from step 3 is needed to configure the Network settings.
Figure 5: Device Setup Screen within Viewpoint