GE MultiNet Instruction Manual

GE MultiNet Instruction Manual

Serial to ethernet converter
Hide thumbs Also See for MultiNet:

Advertisement

GE
Grid Solutions
Instruction Manual
Firmware Revision 1.x
Manual P/N: 1601-0117-A4
GE Publication Number: GEK-106498C
*1601-0220-A4*
MultiNet
Serial to Ethernet Converter

Advertisement

Table of Contents
loading

Summary of Contents for GE MultiNet

  • Page 1 Grid Solutions MultiNet Serial to Ethernet Converter Instruction Manual Firmware Revision 1.x Manual P/N: 1601-0117-A4 GE Publication Number: GEK-106498C *1601-0220-A4*...
  • Page 2 The contents of this manual are the property of GE Multilin Inc. This documentation is furnished on license and may not be reproduced in whole or in part without the permission of GE Multilin. The content of this manual is for informational use only and is subject to change without notice.
  • Page 3: Table Of Contents

    Table of Contents FEATURES ..............................1 DESCRIPTION ............................2 RS485 SERIAL PORT ..........................3 10BASE-F FIBER OPTIC PORT ......................4 INPUT POWER TERMINALS ......................5 MOUNTING ............................6 GETTING STARTED WITH ENERVISTA TO SETUP MULTINET ..........7 CONFIGURATION ..........................10 EXAMPLE: C PQM ............12 ONNECTING ULTI ET TO A...
  • Page 4 TABLE OF CONTENTS TOC–II MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL...
  • Page 5: Features

    IED. • The Multinet-FE is specifically designed for use with the PQMII and other GE serial Modbus IEDs and deployed for use in an Electrical utility or Substation as part of a Large Scale Fixed Installation (LSFI).
  • Page 6: Description

    MultiNet is environmentally hardened to withstand severe utility and industrial conditions. MultiNet can be used to connect an existing Modbus RTU network over RS485 onto a LAN in order to support multiple SCADA masters or advanced HMI systems. Additionally, the use of MultiNet greatly facilitates the setup and wiring of any serial device to a communications center since it avoids costly RS485 cable runs.
  • Page 7: Rs485 Serial Port

    PLC, protection relay or any serial Modbus IED is possible. Connect the “+”, “–“ and common terminal of MultiNet to the “+”, “–“ and common terminals of all the IEDs. Correct polarity must also be observed. For instance, the IEDs must be connected with all RS485 “+”...
  • Page 8: 10Base-F Fiber Optic Port

    Fiber is immune to electrical interference and provides complete isolation. Optical fibers may be connected to the MultiNet supporting a wavelength of 820 nm in multimode. Optical fiber is only available with the MultiNet-FE option (see the Order Code for details).
  • Page 9: Input Power Terminals

    Input Power Terminals The input power terminals are located on the left side of the green terminal block. MultiNet may be connected to either 90 to 265 V AC at 50/60 Hz or 90 to 300 V DC supply power.
  • Page 10: Mounting

    INSTRUCTION MANUAL Mounting MultiNet is DIN rail mountable and ships with two DIN rail clips attached on the rear of the unit. The DIN rail clips can attach the unit onto a standard 35 mm DIN rail. Place the top hooks of the clip against the DIN rail and apply a downward force until an audible click is heard.
  • Page 11: Getting Started With Enervista To Setup Multinet

    INSTRUCTION MANUAL Getting Started With EnerVista to Setup Multinet The MultiNet setup software is provided to edit settings and configure the unit. The setup software connects to the unit through either the 10BaseT (RJ45*) port or the 10BaseF (fiber) port.
  • Page 12 Run the installation program and follow the on-screen instructions. vii Once the installation is complete, click on “IED Setup” on the left panel of the screen. You will see a Multinet icon on the IED screen. Double click on it to launch the MulitNet setup application.
  • Page 13 INSTRUCTION MANUAL MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL...
  • Page 14: Configuration

    Before starting, verify that the Ethernet network cable is properly connected to the Ethernet port on MultiNet. To connect MultiNet directly to the Ethernet port of a PC or laptop, use a crossover cable; to connect MultiNet directly to an Ethernet network, use a regular pass-through RJ-45 cable.
  • Page 15 Under network settings, enter the IP address, Subnet and Gateway of the MultiNet network interface. If these values are not known, consult your network administrator. Under port settings, enter the Baud Rate and Parity bit for the MultiNet serial interface.
  • Page 16: Example: Connecting Multinet To A Pqm

    INSTRUCTION MANUAL EXAMPLE: Connecting MultiNet to a PQM The following steps detail how to use MultiNet in order to connect a PQM to an Ethernet network. Wire COM1 on the back of the PQM to the RS485 terminals on MultiNet. The wiring is detailed in Figure 2: Typical Configuration.
  • Page 17 11. Select the Plug & Play > Create Schema menu item to open the Plug and Play Device dialog box. Ensure that “PQM” is selected within the drop down selection. Click Create to automatically create plug and play screens for the PQM. MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL...
  • Page 18 12. When finished, the plug and play menu will appear, showing our PQM labeled as Quick Connect. Click the Dashboard button below the PQM icon to view the device information. We have now successfully accessed our PQM through MultiNet. FIGURE –7: Plug and Play Menu Showing Attached PQM.
  • Page 19: Example: Configuring A Laptop To Communicate To Multinet Over Crossover Cable

    192.168.1.2 has been assigned to the MultiNet, use that address as the gateway for the laptop. Similarly, set the IP address of the laptop to the gateway IP of the MultiNet. For example, set the laptop IP address to “192.168.1.1” if the gateway IP of the MultiNet is “192.168.1.1”.
  • Page 20 CONFIGURATION section. For this example use the IP address of 192.168.1.2, subnet of 255.255.255.0 and a gateway of 192.168.1.1. Once the configuration of the MultiNet device is complete, return the laptop to its previous settings using the recorded values from step 5. If the MultiNet device was configured properly, communications may be tested on the connected network using EnerVista, as shown in the first example.
  • Page 21: Dimensions

    INSTRUCTION MANUAL Dimensions FIGURE –9: MultiNet Dimensions MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL...
  • Page 22: Order Code

    INSTRUCTION MANUAL Order Code Multinet Modbus RTU to Modbus TCP/IP converter with RS485 communications 10BaseT Ethernet Port, and 10BaseF fiber optic port MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL...
  • Page 23: Specifications

    Power magnetic Immunity IEC61000-4-8 Level 5 Pulsed Magnetic Immunity IEC61000-4-9 1000A/m Damped Oscillatory magnetic IEC61000-4-10 100A/m 0,40,70,80% dips, 250/ Voltage Dip & interruption IEC61000-4-11 300 cycle interrupts Damped Oscillatory IEC61000-4-18/IEEEC37.90.1 2.5KV / 1MHz MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL...
  • Page 24 Manufactured under a ISO 9001 registered program ENVIRONMENTAL Ambient temperatures Operating range: -20°C to 70°C Altitude: 2000m (max) Insulation Class: Pollution Degree: Overvoltage Category: IP10 Front Ingress protection: IP40 top,bottom,back, left/right MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL...
  • Page 25: Warranty

    INSTRUCTION MANUAL Warranty For products shipped as of 1 October 2013, GE warrants most of its GE manufactured products for 10 years. For warranty details including any limitations and disclaimers, see the Terms and Conditions at https://www.gegridsolutions.com/multilin/warranty.htm For products shipped before 1 October 2013, the standard 24-month warranty applies.
  • Page 26 INSTRUCTION MANUAL MULTINET SERIAL TO ETHERNET CONVERTER – INSTRUCTION MANUAL...

Table of Contents