2.2

External Equipment

Cables for the external equipment are connected to the TB Board (05P0758) in the
transceiver unit and ports on the control unit Note that these cables should be fixed to the
cable board at the entrance of cables with cable ties.
Equipment with IEC 61162-1 (NMEA) format
Connects a navigator to the terminal board in the transceiver unit. The FS-5070 can receive
the following sentences in IEC-61162-1 (ed.2nd) format. Use the interconnection cable type
TTYCS-1 (Japan Industrial Standard type, or equivalent) or CO-SPEVV-SB-C 0.2x2P.
GLL: Latitude and longitude
RMC: GPS generic navigation information
GGA: GPS position, UTC
ZDA: UTC, day, month, and year
RMA: Minimum Loran-C data
Priority: GGA>RMC>GLL>RMA
Armor
Inner sheath
Wind vinyl tape.
(For CO-SPEVV-SB-C 0.2x2P)
Fabrication of TTYCS-1 for connection to the transceiver unit
Transceiver unit, inside view
90
Remove the armor by 90 mm.
11 9
Remove the inner sheath by 20 mm,
and the sheath of the cores by 9 mm.
Twist and trim the shield.
Solder a vinyl wire to the shield.
Vinyl wire
Solder a vinyl wire to the shield.
Solder the shield and unused cores.
Soldering
Vinyl wire
TB Board
(05P0758)
TTYCS-1 (Twisted pair cable)
Sheath
Shield
φ =
10.1 mm
Conductor
S = 0.75 mm
φ = 1.11 mm
Armor
2
2-7