Furuno FS-5070 Installation Manual page 32

Ssb radiotelephone
Hide thumbs Also See for FS-5070:
Table of Contents

Advertisement

Distress alert IC-302-DSC/Indicator IC-303-DSC
Use TTYC-4 (Japan Industrial Standard type, or equivalent) or CO-SPEVV-SB-C 0.2X5P
cable and fabricate it as below.
90
Armor
Inner sheath
Twist and trim the shield.
Wind vinyl tape.
Fabrication of TTYC-4 for connection to the transceiver unit
External BK
Terminal No.
Signal name
33
34
36
TX KEYED
37
RX MUTE
38
SHIELD
Note: When GND line from other radiotelephone is connected to the chassis, float the
ground.
External
Battery
2-8
Remove the outer sheath and
armor by 90 mm.
11 9
Remove the inner sheath by 20 mm,
and the sheath of the cores by 9 mm.
Solder a vinyl wire to the shield.
Solder the shield and unused cores.
Soldering
Vinyl wire
Function
BK +
Output voltage: 24 VDC
BK -
GND
Go to GND on transmitting.
Receiver circuit is muted when
this line is GND.
Power terminal
(24VDC)
+
24V
-
Power of BK
φ = 15.5
T-IF Board (05P0757)
J1
+
1
2
-
3
TB5
34
33
TB Board
(05P0758)
BK -
BK +
mm
Armor
Sheath
Conductor
2
S = 0.75 mm
φ = 1.11 mm
TTYC-4
Object
Power of relay BK for
other radiotelephone
0 V
BK control for other
radiotelephone
BK control from other
radiotelephone

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents