Management of SMS on the way out
The control panel has the possibility of sending specific messages according to the events generated..
These messages can be both technical or alarm messages and/or of inputs restore.
Technical Messages: they are related to situations such as supplying anomalies, as battery and
are automatically dialled making use of a library of per-recorded messages.
Zone messages: are related to signalling of zone inputs for both alarm communication, restore and
exclusion.
The zone SMS are dialled by the sequence of 4 standard words to which a zone strip can be
added.
Management of incoming SMS
It is possible to ask the control panel the execution of commands from remote way, using sms
appropriately codified.
The same operations as for the vocal RTC connection can be required.
The incoming sms are executed only if:
• the calling telephone number is associated to a user
• the associated user is enabled to RTC with automatic validation according to telephone
number
• their syntax is correct
• require actions to which the user is enabled
More commands can be put in the end of the same message, provided that:
• the total length is not over 46 characters
• the commands are separated by #
• any command is preceded and followed by #
List of the Commands
Type
oc activation
oc deactivation
control panel arming
control panel disarming
zone exclusion
zone inclusion
sector state request
sectors state request
zone state request Referred to:
Open/Tamper/Excluded/Supervision
zones state request
output state request
outputs state request
system state request
Referred to: technical anomalies
confirm operations
calls block
- Example of CORRECT sequences: #excl 12#excl 15#arm on 2#zones state#
Nota: The exceeding space will be removed
Syntax
#act number_oc#
#deact number_oc#
#act [on|ho|zo|pe] sector#
#sp sector#
#excl number_zone#
#incl number_zone#
#state sector N#
#sectors state#
#state zone N#
#zones state#
#state output N#
#outputs state#
#system state#
#res#
#stop#
- 30 -
Example
#act 13#
#deact 13#
#arm ho 2#
#sp 2#
#excl 12#
#incl 12#
#state sector 2#
#sectors state#
#state zone 2#
#zones state#
#state output 5#
#outputs state#
#system state#
#res#
#stop#
Need help?
Do you have a question about the CAPTURE and is the answer not in the manual?