Preparation Before Installation - Daikin FDMQ09RVJU Installation Manual

R410a split series
Hide thumbs Also See for FDMQ09RVJU:
Table of Contents

Advertisement

<Failure example>
If there is an obstacle in the airflow path or proper installation
space is not provided, the indoor unit will cause air volume
reduction and take in air blown out of the indoor unit,
thus resulting in performance degradation or turning the
thermostat OFF frequently.
CAUTION
• Install the indoor and outdoor units, power supply wiring,
remote controller wiring and transmission wiring at least
1 meter away from televisions or radios to prevent image
interference or noise.
(Depending on the radio waves, a distance of 1 meter may
not be sufficient to eliminate the noise.)
• Install the indoor unit as far as possible from fluorescent
lamps.
If a wireless remote controller kit is installed, the
transmission distance may be shorter in a room where
an electronic lighting type (inverter or rapid start type)
fluorescent lamp is installed.
(2) Use suspension bolts to install the unit.
Check whether or not the ceiling is strong enough to
support the weight of the unit. If there is a risk that the
ceiling is not strong enough, reinforce the ceiling before
installing the unit.

4. PREPARATION BEFORE INSTALLATION

(1) Check the relation of location between the ceiling
opening and the indoor unit suspension bolts. (unit:
inch (mm))
• Provide one of the following service spaces for the
maintenance and inspection of the electrical wiring box
and drain pump or for other services.
1. Inspection ports 1 and 2 (17-11/16 inch (450mm) ×
17-11/16 inch (450mm)) (Fig. 3-2) and a minimum
space of 11-13/16 inch (300mm) at the bottom of the
product (Fig. 3-1).
2. Inspection port 1 (17-11/16 inch (450mm) ×
17-11/16 inch (450mm)) on the electrical wiring box
side and inspection port 2 on the bottom of the
product. (Fig. 4, arrow A-1)
3. Inspection port 3 on the bottom of the product and on
the bottom side of the electrical wiring box. (Fig. 4,
arrow A-2)
Electrical wiring box
Ceiling
< In the case of (1)-1 >
5
Inspection port
unit: inch (mm)
Fig. 3-1
31-1/2 (800)
24-13/16
(Suspension
bolt pitch)
Air outlet
Inspection port 2*
Bottom of
(17-11/16 (450)×
indoor unit
17-11/16 (450))
(For drain pan
removal and
* Inspection port 2 is not required
component
if the bottom space under the product
replacement)
is accessible for work.
Electrical wiring box
Ceiling
Inspection port
Inspection port 1
(17-11/16 (450)×
17-11/16 (450))
31-1/2
Inspection port 2
(800)
(Indoor unit
size or more)
Arrow A-1
< In the case of (1)-2, 3 >
Table 1
B
09/12
39-3/8
1-15/16 (50)
class
15/18/24
27-9/16
(0)
class
(2) Mount canvas ducts to the air outlet and inlet so that
the vibration of the indoor unit will not be transmitted
to the ducts or ceiling. Furthermore, attach sound
absorbing material (thermal insulation material) to
the duct inner walls and anti-vibration rubber to the
suspension bolts (refer to 8. DUCT WORK).
(3) The indoor unit is set to standard external static
pressure.
• If external static pressure is higher or lower than the
standard set value, the remote controller may be used
to make on-site setting change in the external static
pressure.
Refer to 10. FIELD SETTING.
Inspection port 1
(17-11/16 (450)×
(630)
17-11/16 (450))
Suspension bolt (× 4)
Electrical wiring box
Air inlet
B
Fig. 3-2
unit: inch (mm)
A
Inspection
port 3
(Indoor unit size
+ 11-13/16 (300)
or more)
Electrical
wiring box
31-1/2
(800)
Arrow A-2
Fig. 4
unit: inch (mm)
unit: inch (mm)
C
D
40-7/8
51-3/16
(1000)
(1038)
(1300)
29-1/16
39-3/8
(700)
(738)
(1000)
Electrical
wiring box
E
English