INSTALLATION
INSTRUCTIONS
Window
Opening
Requirements
PERSONAL
INJURY/UNIT
OPERATION
HAZARD
Failure
to follow
this caution
may result in personal
injury
and/or damage
to unit components.
It is recommended
to have someone
assist you during
the
installation
of this unit because
the compressor
is located
on
the controls
side of the unit (right side) and this side will be
heavier
and more awkward
to manipulate.
Step 1 --Select
the Best Location
A. Your
room
air conditioner
was designed
to fit easily
into a
single
or
double
hung
window.
However,
since
window
designs
vary, it may be necessary
to make some modifications
for safe and proper
installation.
B. Make
sure window
and frame
is structurally
sound
and free
from dry and rotted wood.
C. For maximum
efficiency,
install the air conditioner
on side of
the house
or building
which favors
more shade than sunlight.
If the unit is in direct
sunlight,
it is advisable
to provide
an
awning
over the unit.
D. Provide
sufficient
clearance
around
the cabinet
to allow
for
ample
air circulation
through
the unit (see Fig. 5). The rear of
the unit should be outdoors
and not in a garage nor inside of a
building.
Keep unit as far away as possible
from obstacles
and
obstructions
and
at least
30"
above
the
floor
or ground.
Curtains
and other objects
within
a room should
be prevented
from blocking
the air flow.
E. Be certain
the proper
electrical
outlet
is within
reach
of the
installation.
Use only
a single
outlet
circuit
rated
at proper
current
(see
table
1 on page
4). All wiring
should
be in
accordance
with local and national
electrical
codes.
F.
Your
unit
was
designed
to evaporate
condensation
under
normal
conditions.
However,
under
extreme
humidity
conditions,
excess
condensation
may
cause
the
basepan
to
overflow
to the outside.
The unit should
be installed
where
condensation
run-off
cannot
drip
on
pedestrians
or
neighboring
properties.
20"
Awning
/
SIZE
MODEL
12K
14K-23K
Cabinet
Size
(W/H/D)
22.8"/15.7"/24.1"
26.5"/18.5"/26.9"
Window Opening
Width
27" - 41"
30" - 44"
Window Opening
16"
18.5"
Height
Step 2 --Preparation
to Remove
the Air Conditioner
Slide-Out
Chassis
A. Remove
total of (4) Philips
screws
securing
the chassis to the
cabinet.
There are (2) screws on each side. The set of screws
closest
to the front
of the unit secure
the front
panel
to the
cabinet.
The set of screw closest
to the rear of the unit secure
the cabinet
to the chassis
(see Fig. 6).
B. Remove
the front
panel assembly
from the cabinet
by gently
pulling
it.
C. Grasp the pull handle
at the front
of the slide-out
chassis
and
carefully
slide the air conditioner
out of the cabinet
(see Fig. 7).
NOTE:
Screws
must
be reinstalled
upon
completion
of the
window
installation
to secure slide-out
chassis.
IMPORTANT:
Please seek assistance
for this procedure.
Right side
PNlips screws
Fig. 6 - Screw
Removal
Coil
A06535
\
Side
obstruction
12" Min.
ence,
wall, or
30" Min.
other
obstacle.
I
Ground
A05534
Fig. 5 - Air Conditioner
Clearances
Pull Handle
Fig. 7 - Air Conditioner
Removal
A06536
Step 3 --Assembly
of the upper
& lower channels
to the
cabinet
A.
" L" Shaped
Top Channel:
Stick the double
adhering
seal to
the " L" shaped
top channel,
and then Install
the "L" shaped
top channel
to the cabinet
as shown
in Fig. 8 using
(5) 1/4"
screws.
B.
"n" Shaped
Bottom
Channel
installed
as shown
in Fig.8
using
(4) 1/4" screws.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kc_223pKh_123pKc_183pKc_233p

Table of Contents