Zaxnet Voting Enable; Zaxnet Dropout Compensator - Zaxcom TRXFB3 User Manual

Table of Contents

Advertisement

Zaxcom TRXFB3
This menu is where the TRXFB3 is assigned a unit code. The unit code is a unique number used to identify each
TRXFB3 within a particular group. This allows individual transmitters within the same group to be independently
controlled. Each transmitter should have a different unit code.
Unit codes can be assigned any number from 1 to 200.

ZaxNet Voting Enable

This menu will only appear if the TRXFB3 is set to receive (RX) mode
ZAXNET VOTING:
NORMAL (OFF)
The purpose of voting is to allow the ZaxNet receiver in the TRXFB3 to choose, and switch to, the stronger
signal from two different ZaxNet transmitters. One purpose of this is if on a large set a second IFB transmitter
can be placed at a different location so the ZaxNet receiver in the TRXFB3 can choose the stronger signal.
Please note that the second ZaxNet transmitting frequency must be set 2MHz higher than the first ZaxNet
transmitter.

ZaxNet Dropout Compensator

ZAXNET DROPOUT
COMPENSATOR ON
This menu enables the ZaxNet dropout compensator. When the TRXFB3 is receiving ZaxNet audio and there is a
brief dropout the IFB dropout compensator looks at the received audio surrounding that dropout and replaces
the lost audio a few samples of audio essentially masking the dropout.
17
ZaxNet Menu

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRXFB3 and is the answer not in the manual?

Questions and answers

Table of Contents