Page 1
TME650/1000 SKOPE Glass Door Vertical Chiller...
Page 2
E-mail: enquiry@skope.co.nz Website: www.skope.co.nz Trademark Infringement The SKOPE trademark on this product is infringed if the owner, for the time being, does any of the following: • Applies the trade mark to the product after their state, condition, get-up or packaging has been altered in any manner •...
SKOPE TME650/1000 Specifications Models This service manual is applicable to the SKOPE TME650 and TME1000 chillers detailed below. The type code is used to distinguish between different models. Model Type code Description TME650 V6070H Single door chiller with fluorescent tube lighting...
Optional sign lighting 1 x 9W T8 LED tube (ø16mm x 600mm) Internal lighting 1 x 22W T8 LED tube (ø16mm x 1500mm) Refrigeration Unit ® Description Top mount SKOPE cyclone refrigeration unit Unit model V6080R-128PSZ Compressor Danfoss SC12G Nominal capacity...
Optional sign lighting 1 x 21W T5 fluorescent tube (ø16mm x 850mm) Internal lighting 2 x 35W T5 fluorescent tube (ø16mm x 1450mm) Refrigeration Unit ® Description Top mount SKOPE cyclone refrigeration unit Unit model V5071R-128PSZ Compressor Danfoss SC18G Nominal capacity...
Optional sign lighting 1 x 12W T8 LED tube (ø26mm x 900mm) Internal lighting 2 x 22W T8 fluorescent tube (ø26mm x 1500mm) Refrigeration Unit ® Description Top mount SKOPE cyclone refrigeration unit Unit model V5084R-128PSZ Compressor Danfoss SC18G Nominal capacity...
Page 9
SKOPE TME650/1000 Notes Specifications Service Manual...
SKOPE TME650/1000 Wiring TME650 (fluorescent lighting) blue blue brown brown Sensors grn/ylw grn/ylw blue blue blue brown brown grn/ylw blue P E N grn/ylw grn/ylw P E N orange brown blue blue white brown brown LEGEND Sign unit Start capacitor...
SKOPE TME650/1000 TME650 (LED lighting) blue blue brown brown Sensors grn/ylw grn/ylw blue blue blue brown brown grn/ylw blue P E N grn/ylw grn/ylw P E N blue brown blue brown brown LEGEND Sign unit Relay Socket box LED tube...
SKOPE TME650/1000 TME1000 (fluorescent lighting) blue blue brown brown Sensors grn/ylw grn/ylw blue blue blue brown brown grn/ylw blue grn/ylw grn/ylw P E N P E N orange brown blue blue brown brown orange white white LEGEND Sign unit Relay...
SKOPE TME650/1000 TME1000 (LED lighting) white blue blue brown brown Sensors grn/ylw grn/ylw blue blue blue brown brown grn/ylw blue grn/ylw grn/ylw P E N P E N brown blue blue brown brown brown blue LEGEND Sign unit Unit junction box...
SKOPE TME650/1000 Door Assembly - TME650 Parts — TME650 Door Item Description SKOPE Part No. Customer Part No. RH door assembly V6000/Z01RT LH door assembly V6000/Z01LT Door gasket GKT4775N Torsion bar assembly REF4295P Capstan TUR5100 Bush PLM5075 Cotter pin (not pictured)
SKOPE TME650/1000 Door Assembly - TME1000 Parts — TME1000 Door Item Description SKOPE Part No. Customer Part No. RH door assembly V5000/Z01RT LH door assembly V5000/Z01LT Door gasket GKT4774N Torsion bar assembly REF4295P Capstan TUR5100 Bush PLM5075 Cotter pin (not pictured)
Fluorescent tube ELL0604 Lamp holder ELZ0600 Parts — Side Light (LED) Item Description SKOPE Part No. Customer Part No. LED RH sidelight assembly V50BV/L85R-32 LED LH sidelight assembly (TME1000 only) V50BV/L85L-32 LED tube ELL10180 Lamp holder ELZ6270 Spare Parts Service Manual...
Due to incompatability with standard electric componentry and flammability, under NO circumstances may a refrigerant utilizing HYDROCARBON be used in this refrigeration system SKOPE INDUSTRIES LIMITED SKOPE AUSTRALIA PTY. LTD. CAUTION: DANGER 220-240 VOLTS Isolate from mains power supply before attempting any...
SKOPE TME650/1000 Unit Assembly - TME1000 WARNING! Due to incompatability with standard SKOPE INDUSTRIES LIMITED SKOPE AUSTRALIA PTY. LTD. electric componentry and flammability, under NO circumstances may refrigerant utilizing HYDROCARBON be used in this refrigeration system. LM620/332 CAUTION: DANGER 220-240 VOLTS...
SKOPE TME650/1000 Replacement Procedures Lighting The chiller will be fitted with either fluorescent or LED light tubes. Before replacing a light tube, determine whether it is fluorescent or LED and replace with the same tube type. Fluorescent and LED tubes are not interchangable.
Fuses The fuse for the cabinet lights and centre pillar (TME1000 only) are located under the ballast cover (below the sign panel). To access the fuses 1.
SKOPE TME650/1000 Fluorescent Fluorescent lit chillers are fitted with light ballasts. The interior light ballast is Ballast located under the ballast cover (below the sign panel). Fluorescent lit chillers fitted with a lit sign have a ballast inside the sign assembly.
SKOPE TME650/1000 Doors Depending on the model, the chiller will be fitted with one or two doors. Alignment This can be achieved by releasing the bottom hinge bracket which is provided with slots allowing alignment adjustment, enabling the bottom of the door to be moved sideways.
SKOPE TME650/1000 Torsion Bar In the event the door tension can no longer be adjusted, the torsion bar may Replacement need replacing. The torsion bar assembly is located inside the door frame. To replace the door torsion bar assembly 1. Disconnect the chiller from the power supply.
SKOPE TME650/1000 Hinge The glass door can be hinged on either the left or right hand side (TME650 Reversal only). To reverse the door hinging 1. Disconnect the chiller from the power supply. 2. Remove the door (see “Door Removal” on previous page).
SKOPE TME650/1000 Drum Thermometer The drum thermometer, which provides a constant display of the cabinet air temperature, is located on the right hand hand side of the cabinet below the sign unit or top panel. The thermometer bulb is located at the port hole on the ceiling of the cabinet interior.
SKOPE TME650/1000 Calibration Once it has been determined that an adjustment is required, the drum thermometer will need to be calibrated. To calibrate the drum thermometer 1. Remove the drum thermometer from the cabinet (see above). 2. Use a small bladed screwdriver to open the drum thermometer body.
SKOPE TME650/1000 Refrigeration Unit Introduction The SKOPE Cyclone® refrigeration unit is a removable, self-contained refrigeration module, which aligns with port holes in the roof of the cabinet. Air is drawn through the evaporator and blown down the cabinet back duct.
SKOPE TME650/1000 Removing the Follow these steps to remove the refrigeration unit from the cabinet. Refrigeration Unit To remove the refrigeration unit 1. Disconnect the chiller from the power supply. 2. Unplug and remove the sign unit or top panel, and remove the sign back and sides.
SKOPE TME650/1000 Unit Junction Electrical connections and components for the refrigeration unit are Box Assembly contained in the unit junction box assembly. The box is mounted on front of the evaporator box near the compressor. To service or replace components inside the unit junction box, remove the cover.
SKOPE TME650/1000 Thermostat The thermostat is pre-set to give an internal air temperature of between 1°C and 4°C, and in normal circumstances should not require adjustment. If thermostat adjustment is required: to make colder - turn clockwise, to make warmer - turn anti-clockwise.
SKOPE TME650/1000 Condenser The condenser fan motor, blade and mounting plate can be removed from the refrigeration unit as a complete assembly. To remove and replace the condenser fan blade 1. Disconnect the chiller from the power supply. 2. Unscrew the mounting...
SKOPE TME650/1000 Evaporator The evaporator fan is fixed to the evaporator fan mounting plate, mounted on the evaporator coil inside the evaporator box. To remove and replace the evaporator fan blade 1. Disconnect the chiller from the power supply. 2. Remove the evaporator box assembly lid to access the interior of the evaporator box.
SKOPE TME650/1000 Compressor The compressor is located at the front of the refrigeration unit, beside the condenser coil. Before replacing the compressor, ensure the compressor electrics are operating correctly and that the compressor is being supplied with consistent voltage over 220 volts. Ensure the voltage does not drop at start- up.
SKOPE TME650/1000 Maintenance Cleaning Cabinet Periodically wipe the inside and outside of the cabinet with a damp cloth, taking care to keep moisture away from electrical parts. As with any maintenance, ensure the cabinet is isolated from the power supply before cleaning.
SKOPE TME650/1000 Troubleshooting Diagnostic For problems with the cabinet and refrigeration unit, use the following table. Table Problem Possible Cause Repair • Cabinet not • Loss of power supply • Check mains power supply. operating • No controller display • Interior light not •...