Jøtul GF 500 DV Portland Installation And Operation Manual page 19

Direct vent gas stove
Table of Contents

Advertisement

Baffle
Assembly
Figure 31.
Baffle Assembly location. Remove two 6 mm nuts to
detach it from the firebox.
Secondary Baffle
Remove wings
Ba e Location / Fuel Conv 1
Figure 33.
Use pliers to break the end wings off the Secondary Baffle.
Figure 35.
Pull the shutter stems forward to increase primary air. Push back to restrict air.
6 mm
Nut
Loosen these
screws.
Air Shutter Stems
Figure 32.
Pull the baffle plate down slightly, then swing the end
forward to remove it from the firebox..
REMOVE TWO #8 SCREWS TO LOOSEN THE
BAFFLE WING. USING PLIERS BEND THE
PERFORATED PORTION OF THE SECONDARY
BAFFLE TILL IT BREAKS AWAY
Figure 34.
Re-secure the modified Secondary Baffle.
BAFFLE COMMING OUT
139760_A GF 500 DV Oct. 2017
REMOVE
BAFFLE W
PERFORA
BAFFLE T
THEN RE-INSTAL
AND THE SECON
THE AS SHOWN.
CORRECT SET U
FOR LP GAS.
19