Samsung AG042KSVANH Installation Manual page 91

Dvm chiller. ag042ksv series; ag056ksv series; ag070ksv series
Hide thumbs Also See for AG042KSVANH:
Table of Contents

Advertisement

A
Model(s) : AG056KSVANH
B
Air-to-water heat pump : yes
C
Water-to-water heat pump : no
D
Brine-to-water heat pump : no
E
Low-temperature heat pump : no
F
Equipped with a supplementary heater : no
G
Heat pump combination heater : no
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump,
H
parameters shall be declared for low-temperature application.
I
Parameters shall be declared for average climate conditions.
Item
(J)
( *)
N
Rated heat output
Declared capacity for heating for part load at indoor temperature 20 °C and
Q
outdoor temperature Tj
Tj = -7 °C
Tj = +2 °C
-
Tj = +7 °C
Tj = +12 °C
T
Tj = bivalent temperature
U
Tj = operation limit temperature
For air-to-water heat pumps
V
Tj = -15 °C (if TOL < -20 °C)
W
Bivalent temperature
Cycling interval capacity for
Y
heating
AB
Degradation co-efficient
(**)
AD
Power consumption in modes other than active mode
AF
Off mode
AG
Thermostat-off mode
AH
Standby mode
AI
Crankcase heater mode
AK
Other items
AL
Capacity control
Sound power level, indoors/
AP
outdoors
AQ
Emissions of nitrogen oxides
AS
For heat pump combination heater
AT
Declared load profile
AV
Daily electricity comsumption
AX
Contact details
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output
(*)
AY
of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
AZ
(**)
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
BA
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
1)
BB
2)
If you are a professional looking for information on non-destructive disassembly and dismantling, please send an email to: erims.sec@samsung.com
Symbol
Value
Unit
(K)
(L)
(M)
Prated
(o)
35
kW
Pdh
28.5
kW
Pdh
20.2
kW
Pdh
12.3
kW
Pdh
8.3
kW
Pdh
34.8
kW
Pdh
34.8
kW
Pdh
-
kW
Tbiv
-10
°C
Pcych
-
kW
Cdh
0.9
-
P
0.040
kW
OFF
P
0.040
kW
TO
P
0.040
kW
SB
P
0.140
kW
CK
variable
(AM)
L
-/83
dB
WA
NOx
-
mg/kWh
-
Q
-
kWh
elec
Http://www.samsung.com
Item
(J)
Seasonal space heating energy
P
efficiency
Declared coefficient of performance or primary energy ratio for part load at
R
indoor temperature 20 °C and outdoor temperature Tj
Tj = -7 °C
Tj = +2 °C
-
Tj = +7 °C
Tj = +12 °C
T
Tj = bivalent temperature
U
Tj = operation limit temperature
For air-to-water heat pumps
V
Tj = -15 °C (if TOL < -20 °C)
For air-to-water heat pumps:
X
Operation limit temperature
Z
Cycling interval efficiency
Heating water operating limit
AC
temperature
AE
Supplementary heater
N
Rated heat output
(*)
AJ
Type of energy input
AK
Other items
For air-to-water heat pumps :
AN
Rated air flow rate, outdoors
For water-/brine-to-water
heat pumps: Rated brine or
AR
water flow rate, outdoor heat
exchanger
AS
For heat pump combination heater
AU
Water heating energy efficiency
AW
Daily fuel consumption
Symbol
Value
Unit
(K)
(L)
(M)
η
131
%
s
COPd
(S)
1.71
-
COPd
2.92
-
(S)
COPd
(S)
5.66
-
COPd
5.87
-
(S)
COPd
2.37
-
(S)
COPd or
2.37
-
PERd
(S)
COPd or
-
- or %
PERd
(S)
TOL
-10
°C
COPcyc or
-
- or %
PERcyc
(AA)
WTOL
-
°C
Psup
-
kW
-
21840
m
3
/h
(AO)
-
-
m
3
/h
(AO)
η
-
%
wh
Q
-
kWh
fuel
English
91

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ag056ksvanhAg070ksvanh

Table of Contents