CAME G4000 Installation Manual

CAME G4000 Installation Manual

Street barrier automation
Hide thumbs Also See for G4000:

Advertisement

STREET BARRIER
11 9G25 E N
AUTOMATION
INSTALLATION MANUAL
G4000 - G4001 - G4000N
EN
English

Advertisement

Table of Contents
loading

Summary of Contents for CAME G4000

  • Page 1 STREET BARRIER 11 9G25 E N AUTOMATION INSTALLATION MANUAL G4000 - G4001 - G4000N English...
  • Page 2: Read Carefully

    Warning Sings (e.g. gate plate). (i.e. that for which it was expressly built for). Any other use is Special instructions and to be considered dangerous. Came Cancelli Automatici S.p.A. advice for users is not liable for any damage resulting from improper, wrongful •...
  • Page 4: Legend Of Symbols

    G0469 - Support for applying the fl ashing light to the cabinet; LB38 – Battery card for connecting 3 12V-7Ah batteries. Important! Check that the safety equipment and accessories are CAME originals; this is a guarantee that also makes the system easy to set up and upkeep.
  • Page 5: Dati Tecnici

    Insulation class: I 4.3 Technical description OPERATOR UNIT 2 mm-thick sheet metal cabinet with galvanised, varnished finish (G4000 RAL=2004, G4000N RAL= rough grey), or 2 mm-thick satin polished stainless steel (G4001), ready to fit all accessories. Inspection door with custom key.
  • Page 6: Preliminary Checks

    4.4 Size measurements Measurements in mm 5 Installation Installation must be carried out by expert qualified personnel and in full observance of regulations in force. 5.1 Preliminary checks Before proceeding with the installation, it is necessary to: • Make sure the area selected for the mounting of the base and for the unit itself presents no hazards; •...
  • Page 7 5.3 Cable list and minimun thickness Type of Length of cable Length of cable Length of cable Connections cable 1 < 10 m 10 < 20 m 20 < 30 m 230V 2F power supply 3G x 1,5 mm 3G x 2,5 mm 3G x 4 mm FROR CEI Photoelectric cells TX...
  • Page 8 5.5 Fitting for unit base The following applications are only examples, as the space required for unit installation and the accessories vary de- pending on dimensions and therefore it is up to the installer to select the best solution. - Prepare a hole to house the fixing base and prepare sheath tubes from the branch pit for the connections.
  • Page 9 5.7 Balancing the boom Barrier G4000 is supplied with spring installed at position B. If the fi nal confi guration of your barrier requires a change in the position of the spring (see illustrations), unlock the gear motor and change the position of the spring.
  • Page 10 M12 nut Pull force M12 lh eye rod 5.8 Right handed/left handed barrier To change sense of rotation, request documentation from your local dealer or contact CAME in your country (see last page, otherwise go to www.came.com). LEFT-HAND RIGHT-HAND barrier...
  • Page 11 6 Description control panel This product is engineered and manufactured by CAME cancelli automatici s.p.a. and complies with current safety regulations. The control panel works on 230V a.c. of power, 50/60Hz frequency. Both command and control devices and accessories are 24V powered. Warning! Accessories must not exceed 20 W overall.
  • Page 12: Main Components

    6.1 Main components Terminal boards for external connections Line fuse Accessories fuse “Select Function” dip-switch Radiofrequency terminal board socket (see table) TCA trimmer: automatic closing time adjustment SENS trimmer: amperometric sensitivity adjustment Button for memorising codes Radio code / automatic closing signal LED 10) Connectors for power supply to motor 11) Connectors for connecting battery charger (LB38) 12) Jumper for control type selection for button in 2-7...
  • Page 13: Electrical Connections

    6.2 Electrical connections Gearmotor, endstop The swing-joint in the picture (which is factory made) is for a left-hand barrier (see par. 5.8). 24V (d.c.) Motor Opening micro-switch Orange Brown Orange Blue Closing micro-switch Power source Terminals for powering up accessories: - a 24V a.c.
  • Page 14 Signalling devices 24V DC – 25W output socie When moving (e.g. the - fl ashing light). DIP 3 on OFF - Flashing during the opening and closing cycles. Operates during the opening and closing cycles and when the barrier is closed. DIP 3 on ON Open barrier pilot light (contact rating: 24V –...
  • Page 15 Safety devices DIR photocells (N.C. )Contact for “immediate closing” Automatic bar closing after an obstacle comes within the range of the safety devices. If unused, set Dipswitch 8 to ON. Contact (N.C.) for “re-opening while closing” DIR photocells - input for safety devices like photocell, compliant with EN 12978.
  • Page 16: Selecting Functions

    6.3 Selecting functions 1 ON Automatic closing enabled; 2 ON Radio command operation “open only” enabled (with radiofrequency card slot); 2 OFF Radio command operation “open-close-inversion” enabled (with radiofrequency card slot); 3 ON 24V voltage in output on terminals 10-E during movement cycles and when in the barrier closed position, enabled;...
  • Page 17 Radio frequency card Only for the AF43S / AF43SM radio frequency cards: - position the jumper as illustrated depending on the series of transmitters used. Lock the radiofrequency card into the electronic card AFTER CUTTING OFF THE POWER SUPPLY (or after disconnecting the batteries). N.B.: the electronic card only recognises the radiofrequency card when the power is on.
  • Page 18 ATOMO See instructions attached to AT01 • AT02 AF43SR radiofrequency card AT04 Memorising Intermittent LED - Keep pressed the PROG button on the electronic board. The LED light PROG will fl ash Radio card ZL 37 - Press the button of the transmitter to be memorie.
  • Page 19 9 Connecting two combined barriers that have a single command - Decide which will be the Master barrier (or pilot barrier, that is, which motor will command both barriers) and which will be the Slave (the motor piloted by the Master). 1) On one of the two control panels, set Dip 7 to ON in order to select the motor controlled externally (SLAVE).
  • Page 20: Safety Instructions

    9 Safety instructions Important safety instructions This product must only be employed for its originally intended use. Any other use is wrong and potentially dangerous. The manu- facturer cannot be held liable for any damages resulting from wrongful, erroneous or negligent uses. Avoid using near mechanical moving parts.
  • Page 21 Periodic maintenance log for end-user (every 6 moths) Signature Date Notes...
  • Page 22: Extraordinary Maintenance

    10.2 Extra-ordinary maintenance The following table serves to note down any extraordinary maintenance, repairs or improvements performed by specialised firms. N.B.: Any extraordinary maintenance must be performed by specialised technicians. Extra-ordinary maintenance log Installer’s stamp Operator name Date of job Technician’s signature Requester’s signature Job performed ________________________________________________________________________________________...
  • Page 23: Demolition And Disposal

    UNI EN ISO 14001 standard to ensure environmental protection. Please continue our eff orts to protect the environment—which CAME considers one of the cardinal elements in the development of its operational and market strategies—simply by observing brief recommendations as regards disposal: DISPOSAL OF PACKAGING –...
  • Page 24 HR • Za sve dodatne informacije o poduzeću, proizvodima i tehničkoj podršci: UK • Для отримання будь-якої іншої інформації про компанію, продукцію та технічну підтримку: www. came.com www. came.com CAME Cancelli Automatici S.p.a. CAME Cancelli Automatici S.p.a. Via Martiri Della Libertà, 15 31030 Dosson Di Casier...

This manual is also suitable for:

G4001G4000n

Table of Contents