Single broadband (single element) transducer
connections (with Speed and Temperature
transducer)
1
2
3
5
Item
Description
1
CP470
2
Dual Speed and Temperature CHIRP transducer
cable (part number A80345)
3
Cable to cable (A80328) connection
4
Cable to transducer connection
5
Single B75/B175 operation cable (part number
A80328)
6
Speed and Temperature transducer
7
Broadband transducer
For a list of transducer cables refer to 10.1 Spares
and accessories.

Transducer cable extension

For some installations it may be necessary to extend
the transducer cable.
• Refer to Chapter 10 Spares and accessories for a
list of suitable transducer extension cables.
• Raymarine recommends a maximum of one cable
extension for any single transducer cable.
• For best performance, keep all cable lengths to
a minimum.
Cable extensions for Wide Beam transducers
All Wide Beam transducers are supplied with a fixed
2 m cable.
You must pair the fixed 2 m cable with an appropriate
extension cable to connect the Wide Beam
transducer to your CHIRP sonar module.
For paired Wide Beam transducer installations,
extension cables must be placed between the
Y-cable and the transducer.
Cables and connections
4
6
7
D13318-1

4.5 Network connection

The unit must be connected to a compatible
Raymarine multifunction display to enable echo
sounder data to be viewed.

Multifunction display connection

Unit connected to a multifunction display using a
RayNet cable.
1
2
Note: The connection panel on your product may
look slightly different to that shown, depending
on variant. The network connection method
remains the same for all products featuring RayNet
connectors.
Item
Description
1
Sonar module (CP370 illustrated).
2
Connector panel for compatible Raymarine
multifunction display.
3
RayNet cable.
Multifunction display configuration (extended
cables)
When the required length of a single network cable
run is greater than 20 m (65.6 ft), a RayNet (male)
to (male) adaptor cable should be used to connect
RayNet cables together .
2
3
4
Note: The connection panel on your product may
look slightly different to that shown, depending
on variant. The network connection method
remains the same for all products featuring RayNet
connectors.
Item
Description
1
Sonar module (CP370 illustrated).
2
Connector panel for compatible Raymarine
multifunction display.
3
RayNet cables.
4
RayNet (Male) to (Male) adaptor cable.
3