7. Suction Strainers (in tank)
REMOVE FILL CAP PLATE FROM
TANK TO GAIN ACCESS TO
STRAINERS
Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation, remove
and clean at time of hydraulic oil change.
3121156
SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
– JLG Lift –
8. Oil Change w/Filter - Deutz
Lube Point(s) - Fill Cap/Spin-on Element
Capacity - 11 Quarts Crankcase; 5 Quarts Cooler
Lube - EO
Interval - Every Year or 1200 hours of operation
Comments - Check level daily/Change in accordance with
engine manual.